User levels
User rights
Password (factory set‐
tings)
Authorized client
Show parameters and measured values
Change parameters
client
Service
Show parameters and measured values
Change parameters
Run firmware update
servicelevel
NOTE
Change the passwords during initial commissioning to protect your device.
It is possible to change the password when you are logged in:
>
Device
>
Change password
> Enter data.
The hash value of the password defined in SOPAS ET is needed for a parameter change
using the RS-422 interface and the Ethernet interface,
see "Setting authorization for
for RS-422 and telegram listing Dx1000 (English, part
number 8021820) for Ethernet.
Example: Hash value “81BE23AA” corresponds to the password “servicelevel”.
Hash values can be calculated:
>
Functions
>
Calculate hash value
> Enter data.
NOTE
Password forgotten?
Please contact SICK service to reset to the factory settings.
Information about the device is displayed in the device window (
>
Device
>
Open
) and
the device can also be configured here.
NOTE
Changes to parameters that are made in SOPAS ET are not saved automatically in
the device. After you have completed the configuration, you must save it in the device
permanently by pressing the
Save permanent
button.
7
OPERATION
62
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice