Module
Contents
Description
Type
Size
Relative address
30
I/O interface QA/Q2
No process data
QA/Q2 Type
Parameter
1 byte
0.0
Active state
Parameter
1 byte
1.0
Output function
Parameter
1 byte
2.0
Distance function
Parameter
1 byte
3.0
SP 1 - Dto / Window / 4 mA [mm]
Parameter
4 bytes
4.0
SP 2 - Window / 20 mA [mm]
Parameter
4 bytes
8.0
Distance hysteresis [mm]
Parameter
4 bytes
12.0
Monit. direction object speed
Parameter
1 byte
16.0
Speed switch point [mm/s]
Parameter
4 bytes
17.0
Hysteresis object speed [mm/s]
Parameter
4 bytes
21.0
Warning / error laser
Parameter
1 byte
25.0
Error hardware
Parameter
1 byte
26.0
Error measurement
Parameter
1 byte
27.0
Warning / error temperature
Parameter
1 byte
28.0
Warning / error ambient light
Parameter
1 byte
29.0
Warning firmware
Parameter
1 byte
30.0
Warning dig. outp. short circuit
Parameter
1 byte
31.0
Alignment laser active
Parameter
1 byte
32.0
Measuring laser active
Parameter
1 byte
33.0
Heating active
Parameter
1 byte
34.0
No echo suppression warning
Parameter
1 byte
35.0
No echo warning
Parameter
1 byte
36.0
3.7.4.8
Module 1 - Distance/i2w
This module reads the current distance value and configures the distance resolution.
The distance value depends on the settings for offset, measuring direction and resolu‐
tion.
Parameters
Values
Distance resolution
1 [mm]
10 [mm]
100 [mm]
Free [µm]
Free distance resolution
1 ... 1000000 [µm]
3.7.4.9
Module 2 - Speed/i2w
This module reads the currently speed value and configures the speed resolution. The
speed depends on the set resolution.
Parameters
Values
Speed resolution
1 [mm/s]
10 [mm/s]
100 [mm/s]
Free [µm/s]
Free speed resolution
1 ... 1000000 [µm/s]
3
PRODUCT DESCRIPTION
32
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice