Distance [m]
Signal level
PL240DG
PL560DG
PL880DG
5
9400
9400
9400
50
7500
7500
7500
100
6200
6200
6200
200
5000
5000
5000
500
1600
3300
3400
1000
850
1500
1850
1500
-
450
800
A step-by-step process is recommended for alignment:
1.
Bring the distance sensor and measuring object close together.
2.
Align the distance sensor so that the light spot of the measuring laser hits the
center of the reflector or the natural object or the level maximum for this distance
is displayed.
3.
Increase the distance between the distance sensor and measuring object. The
light spot must continue to hit the center of the reflector or the natural object or
the level maximum for the respective distance must be displayed.
Proceed as follows to align the distance sensor:
3
4
1
2
X
Figure 16: Align the distance sensor with alignment bracket in the X-direction
5
MOUNTING
48
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice