Example
■
s
max
: 200 m
■
Calculation: a ≥ 0.2 m + 0.004 x 200 m = 1 m
5.6
Mounting the alignment bracket and distance sensor
The distance sensor is mounted using the optional alignment bracket BEF-AH-DX1000
(part number 2080392).
1.
Mount the alignment bracket above the four slotted holes. The alignment bracket
is suitable for mounting on horizontal and vertical surfaces.
1
3
2
Figure 13: Alignment bracket mounting on vertical surfaces
1
Mounting surface
2
Alignment bracket
3
Mounting screw, M5 hexagon socket screw
1
3
2
Figure 14: Alignment bracket mounting on horizontal surfaces
1
Mounting surface
2
Alignment bracket
3
Mounting screw, M5 hexagon socket screw
2.
Loosen hexagonal socket screw.
3.
Insert the distance sensor into the alignment bracket.
5
MOUNTING
46
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice