Product type
DL1000
DT1000
Typical light spot size
W x H (distance)
5 mm x 20 mm (at 1 m)
20 mm x 20 mm (at 5 m)
35 mm x 25 mm (at 10 m)
150 mm x 50 mm (at 50 m)
290 mm x 80 mm (at 100 m)
570 mm x 140 mm (at 200 m)
4,200 mm x 920 mm(at 1,500 m)
5 mm x 20 mm (at 1 m)
20 mm x 20 mm (at 5 m)
20 mm x 20 mm (at 10 m)
20 mm x 20 mm (at 50 m)
20 mm x 20 mm (at 100 m)
20 mm x 20 mm (at 200 m)
Filter
Rain and snow filter
Fog filter
Moving average distance value
Kalman filter
Moving average speed value
Maximum object tem‐
perature
n/a
+1,400 °C
Additional function
Selection of the relevant distance and signal level range, selection of
first or last echo in the selected distance and signal level range
Average service life
of measurement laser
(at 25 °C)
100,000 hours
1
With max. ambient light 100 kLux sunlight
2
On “diamond grade” reflective tape (DG983)
3
Dependent on reflector size and measurement cycle time
4
Dependent on remission factor and measurement cycle time
5
6% ... 90% remission factor
6
Data interface resolution
7
1 σ statistical error, ambient conditions constant, min. power-up delay of 15 minutes
8
At T = +23 °C and after warm-up time > 15 minutes
9
Values apply for “Axial object tracking” measurement mode with factory settings (measurement cycle
time 4 ms, Kalman filter on, speed filter 10 cycles)
10
Values apply for the following settings: Rain and snow filter deactivated, distance average filter deacti‐
vated (filter depth 1 cycle)
11
For high-temperature applications (typically > 1,200 °C) when the the “Ambient light” warning or error
occurs: only with optional additional filter for high-temperature applications (part number 2088511).
11
TECHNICAL DATA
104
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
8024560/1A19/2021-06-30 | SICK
Subject to change without notice