Data transmission
rate in Bit/s
STX/ETX protocol
CR/LF protocol
Distance
Di
status
Di
RRS or
di
speed
Distance
Di
status
Di
RRS or
di
speed
57600
3.0
4.5
4.0
2.0
3.5
3.0
115200
1.5
2.5
2.0
1.5
2.0
2.0
230400
1.0
1.5
1.5
1.0
1.5
1.0
250000
1.0
1.5
1.0
1.0
1.0
1.0
3.7.3.2
Commands
The following variables or methods can be read, written or executed via the RS-422
interface.
Table 13: Commands and responses
Description
Command
Response
Read
sRN
sRA
Write
sWN
sWA
Method
sMN
sAN
3.7.3.2.1
Setting authorization for parameter change
If device parameters need to be changed, the user must activate the access mode (“log
in”). Changes become active when the access mode is set back to “Run” (“log out”).
Log in and log out must be done separately for each parameter. It is not possible to
change several parameters with a single login.
Executing a special command is required for permanent saving of the changed parame‐
ters before logging out,
see "Special functions", page 24
.
Previously activated continuous data is interrupted by the “Activate access mode” func‐
tion. Continuous data output is restarted with the “Deactivate access mode” function.
Table 14: Syntax: Setting authorization for parameter change
Designation
Syntax
Activate access mode
1
--> Response (0 = error, 1 =
success)
= "Log in"
<STX>sMN SetAccessMode 4 81BE23AA<ETX>
<STX>sAN SetAccessMode <[0,1]><ETX>
Deactivate access mode
--> Response (1 = success)
= "Log off"
<STX>sMN Run<ETX>
<STX>sAN Run <[0,1]><ETX>
1
“81BE23AA” is the hash value of the password at the time of delivery (“servicelevel”) for the user level
“Service”. If the password has been changed, the respective hash value must be entered here,
"Parameterization via SOPAS ET", page 61