Environmental influences
■
Comply with technical data, such as the permitted ambient conditions for opera‐
tion of the device (e.g., temperature range, EMC interference emissions, ground
potential),
■
To prevent the formation of condensation, avoid exposing the device to rapid
changes in temperature.
■
Protect the device from direct sunlight. The prevents additional external heating
and potential optical dazzle of the device.
Mounting
■
The device must only be mounted using the pairs of blind tapped holes provided
for this purpose.
■
Mount the device in a shock and vibration insulated manner.
Equipment required
■
Mounting device (bracket) with sufficient load-bearing capacity and suitable
dimensions for the device.
■
2 x M5 screws – the maximum screw-in depth in the device is 5 mm from the
housing surface
NOTE
The screws are for mounting the device on mounting equipment (bracket) supplied
by the user. Screw length is dependent on the mounting base (wall thickness of
the bracket). When using an optional SICK bracket, the screws for mounting the
device are included in the scope of delivery for the bracket.
■
Tool and tape measure
5.3.2
Mounting device
The device is mounted on the bracket using at least two M5 blind hole threads that are
in pairs on both of the narrow sides of the device,
.
The device can be installed using optional SICK brackets or customer-specific brackets.
SICK offers prefabricated brackets which are optimally suited for the mounting of the
device in a wide range of applications. See:
Example: The design of the bracket with adapter plate supports many different installa‐
tion variants, for example, as well as the alignment of the device in two axes.
Figure 14: Example mounting of a device with bow-shaped mounting bracket (SICK accessories,
illustration of the device can differ)
MOUNTING
5
8019588/129Z/2019-02-07 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x
29