Operating Instructions
Chapter
5
CLV 480 Bar Code Scanner
8 010 080/O824/10-02-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-19
Electrical installation
¾
Connect the sensors as shown in
For connecting the host interface via the AMV/S 60 Connection Module, see the Operating
Instructions
"AMV/S 60 Connection Module"
(no. 8 008 296).
Input
"IN X"
CLV "I/O" connection
Pin Y
AMV/S 60
Terminal Z
IN 0
Pin 6
T. 22
IN 1
Pin 2
T. 23
IN 2
Pin 7
T. 24
IN 3
Pin 11
T. 25
IN 4
Pin 12
T. 26
Table 5-18: Pin and terminal assignment for "IN 0" to "IN 4" switching inputs
Function
Trigger source for dynamic focus control
"IN 3" alternative: – trigger source for One Shot on oscillating mirror
"IN 4" alternative: – trigger source for One Shot on oscillating mirror
– encoder increment input
– trigger source for end of reading interval
Default setting "IN 3" and "IN 4": dynamic focus control
Switching mode
Active when input energized (high)
Properties
– Optodecoupled, non-interchangeable
– Can be connected to PNP output on a sensor
Electrical values
Low: –30 V
≤
V
I
≤
+2 V
High: +7 V
≤
V
I
≤
+13 V
Table 5-19: Characteristic data of the "IN 0" to "IN 4" switching inputs
Switching inputs
Content Assignment Table Distance Config.
2
)
Logic state
1)
"IN 4 to IN 0"
inputs
Assignment
table index
Default setting
Example:
Photoelectric switches
(bright switching)
0 0 0 0 0
N 1
DC 1
DC 6
0 0 0 0 1
N 2
DC 2
DC 5
0 0 0 1 0
N 3
DC 3
DC 4
0 0 0 1 1
N 4
DC 4
DC 4
0 0 1 0 0
N 5
DC 5
DC 3
0 0 1 0 1
N 6
DC 6
DC 3
0 0 1 1 0
N 7
DC 7
DC 3
0 0 1 1 1
N 8
DC 8
DC 3
0 1 0 0 0
N 9
DC 8
DC 2
0 1 0 0 1
N 10
DC 8
DC 2
0 1 0 1 0
N 11
DC 8
DC 2
0 1 0 1 1
N 12
DC 8
DC 2
0 1 1 0 0
N 13
DC 8
DC 2
0 1 1 0 1
N 14
DC 8
DC 2
0 1 1 1 0
N 15
DC 8
DC 2
0 1 1 1 1
N 16
DC 8
DC 2
1 0 0 0 0
N 17
DC 8
DC 1
1 0 0 0 1
N 18
DC 8
DC 1
1 0 0 1 0
N 19
DC 8
DC 1
1 0 0 1 1
N 20
DC 8
DC 1
1 0 1 0 0
N 21
DC 8
DC 1
1 0 1 0 1
N 22
DC 8
DC 1
Table 5-20: Dynamic focus control: switching inputs/distance configuration assignment table