Appendix
10.3
Installing and operating the external parameter memory
The external parameter memory is available as an accessory. It is located in a connector
cover and comprises a permanent, rewriteable memory (EEPROM) with 4 kByte from CLV
firmware V 2.0. The connector cover covers the two connections of the CLV in the enclosure
rating IP 65. The cover is shown in
.
Two connection cables that are secured by
means of conduit thread connections supply the signals of the CLV.
Notes
If the CLV 480 is used to replace a CLV 265/CLV 295 equipped with a connector cover (pa-
rameter memory), the CLV 480 cannot store its extensive parameter set in this external pa-
rameter memory (too small).
The external parameter memory is available in different implementations:
10.3.1
Function
When it is started, the CLV is initialized with the data stored in its internal parameter set. If
this parameter set has been copied to an external memory, the device can be replaced ea-
sily. The replacement device, therefore, does not have to be configured manually. Instead, it
accesses the external parameter memory automatically (assuming that the correct start
option has been selected). It then imports the parameter set to its RAM. This option is set
by default. The "Device Ready" and "Read Result" LEDs indicate whether the external me-
mory was accessed successfully. The CLV also outputs messages for troubleshooting pur-
poses on the terminal interface.
Fig. 10-22: External parameter memory, installed on the CLV
22
(0.86)
22
(0.86)
88.5
(3.48)
50
(1.79)
27
(1.06)
27
(1.06)
Order no.
Two Connection cables with
CLV
Length
Connection
2 020 307
Two 15-pin D Sub HD plug connections
(pin assignment identical to device connec-
tions)
Without
heater
3 m (9.84 ft)
CLV to AMV/S 60
AMV 30-071 and BMV 10
2 020 981
Two open cable ends
Without
heater
3 m (9.84 ft)
CLV to non-Sick Power pack, free wiring
2 020 308
One 9-pin D Sub cable connector and one
open cable end
Without
heater
3 m (9.84 ft)
CLV to BMS 20
2 021 689
Two 15-pin D Sub HD plug connections in
plug cover (
without
wires for CAN interfaces)
With
heater
3 m (9.84 ft)
CLV to AMV 100/200
2 027 543
Two 15-pin D Sub HD plug connections in
plug cover (
with
wires for CAN interface 1)
With
heater
3 m (9.84 ft)
CLV to AMV 100/200
Table 10-4: External parameter memory