Electrical installation
For connecting the host interface via the AMV/S 60 Connection Module, see the Operating
Instructions
"AMV/S 60 Connection Module"
(no. 8 008 296).
Terminating the RS 422 interface
The interface can be terminated in the Connection Module. See the Operating Instructions
"AMV/S 60", "AMV 30.071", "AMV 100/200",
or
"BMS 20 Connection Modules".
Activating the RS 232 interface:
The RS 232 interface can be activated with the "CLV-Setup" program:
1.
Choose the H
OST
I
NTERFACE
tab.
2.
Choose the RS 232 option from the H
ARDWARE
drop-down list under D
ATA
FORMAT
.
3.
Download the data to the CLV by clicking
in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is displayed.
4.
Confirm the dialog box by choosing P
ERMANENT
.
The CLV uses the RS 232 version of the host interface.
Tip
The communication parameters can be changed, if necessary, on the H
OST
I
NTERFACE
tab.
To do so, change the values under D
ATA
F
ORMAT
and I
NTERFACE
P
ROTOCOL
.
5.5.5
Connecting the CAN interface
Instructions for the connection of CAN-interface 1 and for configuration of the CLV to use
the device in the SICK-specific CAN Scanner Network or in a CANopen network see the
Operating Instructions
“Application of the CAN interface“
(no. 8 009 180, English edition).
5.5.6
Connecting the PC
The CLV is operated and configured with the PC-based "CLV-Setup" program. In order to do
so, you must connect the device to the PC via the terminal interface (auxiliary interface). Un-
like the host interface, the terminal interface has a permanent data format and a fixed data
transfer rate.
shows how the terminal interface is connected. The cable length
should not be more than 10 m (32.8 ft).
1.
Switch off the PC and power supply to the SICK Connection Module.
2.
Connect the PC to the internal, 9-pin "Service" plug on the Connection Module.
To do so, use a 3-core RS 232 data cable (null modem cable), e. g. no. 2 014 054
(RxD and TxD crossed).
– or –
Without the SICK Connection Module:
Connect the PC as shown in
Fig. 5-3:
Connecting the terminal interface
RS 232
( ) = 9-pin Sub D
plug at PC
or 9-pin "Service"
AMV 60-011/AMS 60-012, -013
Terminal assignment
plug