Chapter
8
Operating Instructions
CLV 480 Bar Code Scanner
8-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 080/O824/10-02-2005
Troubleshooting
6.
"warning: additional
unknown parameter(s),
external parameters
loaded"
(Error type: 101, 114)
Start option: S
TART
WITH
E
XTER
-
NAL
P
ARAMETERS
.
The CLV has successfully
loaded the external parameter
set with tolerated errors
1)
to its
RAM.
Transfer ok but different para-
meter versions in the external
memory and the CLV.
Upload the parameter set to CLV-
Setup and check the values
1)
.
1) The software of the parameter set in the CLV is older than that of the parameter set in the external memory:
print out the parameter set using CLV-Setup. If necessary, display the ID of the unknown/errored command group(s) using the <STX> 8?ERR <ETX> command in the
Terminal Emulator window of CLV-Setup. Decode the ID using the reference manual entitled Command Language of the CLV Bar Code Scanners (on request) and check
the relevant parameter values in the tabs.
The software of the parameter set in the CLV is newer than that of the parameter set in the external memory:
all of the new parameters in the CLV are set to the default values. If these parameters are necessary, edit the values in the relevant tabs in CLV-Setup and download them
to the CLV and the external memory.
Message
Meaning
Possible cause
Remedy
Table 8-3: Messages for problems accessing the external parameter memory (contd.)