Example
180 mm
150 mm
S
L
Figure 15: Recommended fitting height
S
L
120 mm
150 mm
Figure 16: Recommended fitting height for inverted mounting
where:
•
S
L
= protective field length
4.3.7
Access protection
Overview
The safe multibeam scanner is mounted with a vertical scan plane in a stationary
application where access to the hazardous area is at a defined point.
For access protection, the safe multibeam scanner detects an intrusion by a whole
body. The protective field is orthogonal to the approach direction and the safe multi‐
beam scanner is mounted before or after the passage.
4
PROJECT PLANNING
26
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice