Error tolerance for CAN_HI/
CAN_LO
-30 V ... 30 V
4)
1)
The power supply unit must be able to jumper a brief power failure of 20 ms as specified in IEC 60204-1.
Suitable power supply units are available as accessories from SICK.
Battery-powered systems must be able to jumper brief power failures of 5 ms.
2)
A fuse with a maximum rated current of 2 A (slow blow) must be installed in the power supply circuit to
the device in order to limit the available current.
3)
The system is intended for operation with power sources with a nominal voltage of 12 V to 24 V.
4)
Every CAN bus node must be supplied with a maximum supply voltage of 30 V. If the supply voltage is
> 30 V (e.g., 48 V battery system), measures must be taken to limit the CAN voltage to < 30 V in the
event of a fault.
7)
All control inputs must be powered from the same voltage supply as the safe multibeam scanner.
Table 57: Mechanical data
Dimensions (W × H × D)
160 mm x 43 mm x 56 mm
Weight
0.17 kg
Housing material
Durabio (front part, black)
Polycarbonate (back part, colza yellow)
Housing color
RAL 9005 (black) and RAL 1021 (colza yellow)
Table 58: Ambient data
Enclosure rating
1)
IP65 (IEC 60529)
Ambient light immunity
≤ 10 klx
2)
Ambient operating tempera‐
ture
0 °C … 50 °C
Storage temperature
–30 °C … 70 °C
Air humidity
15% ... 95%, non-condensing
3)
Height above sea level during
operation
≤ 3,000 m
EMC
According to IEC 61496-1, IEC 61000-6-2, IEC 61000-6-3
Vibration resistance
4)
Standards
•
IEC 60068-2-6
•
IEC 60068-2-64
•
IEC 60721-3-5
•
IEC TR 60721-4-5
•
IEC 61496-3
Class
5M1 (IEC 60721-3-5)
Sinusoidal vibrations
•
0.35 mm, 50 m/s
2
, 10 Hz … 55 Hz
•
1.5 mm, 2 Hz … 9 Hz
•
5 m/s
2
, 9 Hz … 200 Hz
Noise vibrations
•
0.5 m
2
/s
3
, 5 Hz … 200 Hz
•
0.1 m
2
/s
3
, 200 Hz … 500 Hz
Shock resistance
4)
Standards
•
IEC 60068-2-27
•
IEC 60721-3-5
•
IEC TR 60721-4-5
•
IEC 61496-3
Class
5M1 (IEC 60721-3-5)
Single shock
50 m/s
2
, 11 ms
TECHNICAL DATA
13
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
101