Object
Sub
Access Object name
Default value Type
Description
0x16 RO
Range21
0
UNSIGNED16
0x17 RO
Range22
0
UNSIGNED16
0x18 RO
Range23
0
UNSIGNED16
0x19 RO
Range24
0
UNSIGNED16
0x1a RO
Range25
0
UNSIGNED16
0x1b RO
Range26
0
UNSIGNED16
0x1c RO
Range27
0
UNSIGNED16
0x1d RO
Range28
0
UNSIGNED16
0x1e RO
Range29
0
UNSIGNED16
0x1f RO
Range30
0
UNSIGNED16
0x20 RO
Range31
0
UNSIGNED16
0x6205
Environment data
Ambient data
0x00 RO
NoOfObjects
3
UNSIGNED8
0x01 RO
SupplyVoltage
0
UNSIGNED16 Supply voltage in
mV
0x02 RO
Temperature
0
UNSIGNED16 Temperature inside
the device in °C
0x03 RO
AmbientLightIn‐
tensity
0
UNSIGNED16 Intensity of the
ambient light
The device out‐
puts the maximum
measured value
of the segments
that have been
assigned to a con‐
figured monitoring
case.
0x6206
Signal strength
Signal intensity of a
detected object for
the segments 1-32
in dB
The value
increases as the
object distance
decreases or the
object remission
increases.
The reference value
of the dB value
is the switching
threshold for object
detection.
0x00 RO
NoOfObjects
32
UNSIGNED8
0x01 RO
SignalStrength0
0
UNSIGNED8
0x02 RO
SignalStrength1
0
UNSIGNED8
0x03 RO
SignalStrength2
0
UNSIGNED8
0x04 RO
SignalStrength3
0
UNSIGNED8
0x05 RO
SignalStrength4
0
UNSIGNED8
0x06 RO
SignalStrength5
0
UNSIGNED8
0x07 RO
SignalStrength6
0
UNSIGNED8
0x08 RO
SignalStrength7
0
UNSIGNED8
4
PROJECT PLANNING
54
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice