manualshive.com logo in svg
background image

00'''

UNIVERSAL SENDER KIT INSTALLATION INSTRUCTIONS

Temperature and/or Pressure Senders for use with Electrical Temperature and/or Pressure Gauges

VDO

®

PARTS LIST – TEMPERATURE SENDER KIT

Item   Description

 Quantity  Part number

1      Temperature Sensor (250° Kit)

1

323 900

Or    Temperature Sensor (300° Kit)           1             323 905
2..    1/4" – 18NPT bushing (adapter)         1
3.     3/8" – 18NPT bushing (adapter)  

1

4.     1/2" – 18NPT bushing (adapter)  

1

5.     1/4" Female spade Terminal               1

 

Tools/Items Needed to Complete Installation:
9/16" (14mm) Wrench
Wire Cutter/Stripper
Pliers or other crimping tool
a length of 16 – Gauge insulated wire

---IMPORTANT---

For best results, install your sender in the order described in 
these instructions.  DO NOT USE TEFLON TAPE.  Tape 
keeps the sender from grounding itself properly.  For the 
same reason, do not use Lok-Tite of any sort.  Finally, if you 
are installing a temperature sender, make absolutely sure 3-
5mm of the sender is immersed in fluid.  Mount only in the 
engine block; mounting in the cylinder head will result in 
faulty readings.

I.  Installing the VDO Universal Temperature Sender

There are three bushings included in this kit – one is 1/4-18 NPT; 
another is 3/8"-18NPT; and the third is 1/2"-NPT.  The fitting on the 
sender itself is 1/8-18NPT.  Decide which bushing, if any, you will 
need to adapt the sender to the opening in your engine block.  
Discard the rest, or save them for use later in another project.  But 
be aware that you will have left-over bushings after you complete 
your installation.

1.  Select a location for mounting the temperature sender.  The 
location must be in the engine block – note in the cylinder head, 
where exhaust heat would cause faulty readings. 
2.  Take the correct bushing, if needed, and screw it tightly onto the 
send with your fingers.

Diagram B

Proper Wiring Between Gauge and Temperature Sender

3.  Clean the opening in the engine block where the 
sender unit will be inserted.  Clean threads are 
absolutely necessary if a good ground and reliable 
operation are to be obtained.  
4.  Screw the sender unit finger-tight into the engine 
block.
5.  Use a 9/16" (14mm) wrench to crank the sender into 
the block until it is secure.  As you crank, you will tighten 
the bushing into the block and the sender into the 
bushing.  Keep tightening until the sender assembly is 
snug.  Do not over-tighten.  The sender unit is self-
sealing, and will not leak.

II.  Wiring the VDO Universal Temperature Sender

1.  Either run a new wire to the temperature gauge or find 
the existing wire if a gauge is already installed.
2.  Crimp the supplied 1/4 female spade terminal onto 
the sender end of the wire. (Replace any old connectors 
on an existing wire with the new spade terminal.)
3.  Push the spade connector onto the "thumb tack" 
terminal at the end of the send as show in Diagram A.  
4.  Maker sure the other end of the signal wire is properly 
connected to the gauge (see Diagram B).
5.  Power up the gauge, and make sure it is working.  If it 
isn't, recheck your wiring end and refer to the 
troubleshooting guide on the other side of this instruction 
sheet.

0 511 012 260    09/08

Отзывы: