7.6.7
Transmit PDO (TPDO)
Overview
On the
Transmit PDO (TPDO)
page, you can find an overview of all available Transmit PDOs
and can activate the individual TPDOs. Once you have activated a TPDO, you can adjust
the CANopen parameters for the TPDO (e.g., the COB-ID).
1
Overview of the selected TPDO (highlighted in blue)
2
Settings for the selected TPDO
3
Overview of other TPDOs
Changing the settings
You always change the settings for the currently selected (highlighted in blue) TPDO. To
select a different TPDO, click on the header with the name of the TPDO (e.g., TPDO1).
You can use the
Enable object
checkbox to activate or deactivate the selected TPDO for
the safe multibeam scanner.
You can change the following CANopen parameters for an activated TPDO:
•
COB-ID
: Enter the ID of the TPDO for the communication within the network.
°
You can enter a value between 385 (0x181) and 1,727 (0x6BF).
•
Transmission type
: Enter a value between 0 and 255 for the transmission type for
the TPDO.
°
0 = synchronous (acyclic)
°
1 … 240 = synchronous (cyclic, n * sync)
°
252 = RTR (synchronous)
°
253 = RTR (event-driven)
°
255 = event-driven
•
Inhibit time
: Enter a value between 0 and 65,535 for the transmit delay time for the
TPDO.
•
Event timer
: Enter a value between 0 and 65,535 for the time, after the elapse of
which the TPDO automatically sends a TPDO (transmission period).
7
CONFIGURATION
80
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
8025990/2021-03-03 | SICK
Subject to change without notice