LCR-Reader-MP Manual
Siborg Systems Inc.
21
Waveform
Sine, Square, Triangle
Maximum Frequency
100 kHz
* with the input impedance of the device 1 kOhm
** depending on the position of the extended voltage measurement range switch
14.2 FCC Compliance
Complies with ICES-003 Issue 6 and FCC Part 15.109.
ETC Report produced by MPB Technologies No.: s57e17a242 Release 1 of August 30, 2017.
14.3 General Information
Type of Indicator
Monochrome graphic LCD display with backlight
Power
Battery
Lithium-Polymer (Li-Poli) 3.7V 250 mAh
Typical Recharge Time
2.5 hours
Continuous Operating Time
Over 8 hours (non-illuminated display)
Auto-off
10 - 990 seconds (default 120s)
Use Conditions
10 -
40⁰С and relative humidity up to 80%
Dimensions
Device
180x30x16mm
Case
205x80x25mm
Unit Weight
45 g
Weight of the Device and Case
103 g
14.4 Details of the Measurement Modes
14.4.1
Test Signal Generator
Test Frequency
50Hz, 100Hz, 120Hz, 1kHz,
10kHz, 20kHz, 30kHz,
40kHz,50kHz, 60kHz, 75kHz
100kHz
Constant Pressure
Frequency Setting Accuracy
0.01%
1.5%
-
Test Signal Level
0.65±0.05 Vrms*, 0.1±0.01 Vrms, 0.1±0.01 V**
±(n±0.1) V,
where n=1.2,1.5,2.7
Output Impedance
1000 Ohm
*
At the test frequency 30 kHz ± 0.53±0,04 Vrms.
**No manual selection of the signal level, measurement accuracy 10% + 5.
14.4.2
Resistance
Range
Resolution
Level
Test Frequency
Equivalent
Circuit
100 Hz, 120 Hz
1 kHz
10kHz
20kHz-100kHz
10Ω
0.001Ω
0.1Vrms
-
-
-
-
Series
0.65 Vrms
1%+20
0.5%+20
0.5%+20
1%+20
100Ω
0.01Ω
0.1Vrms
2%+3
1%+3
1%+3
3%+3
Series
0.65 Vrms
1%+3
0.3%+3
0.3%+3
1%+3
1кΩ
0.1Ω
0.1Vrms
1%+5
0.5%+5
1%+5
2%+5
Series
0.65 Vrms
0.5%+2
0.2%+2
0.2%+2
0.5%+2
10кΩ
0.001кΩ
0.1Vrms
1%+5
0.5%+5
1%+5
1%+5
Series,
Parallel
0.65 Vrms
0.5%+2
0.2%+2
0.2%+2
0.5%+2
100кΩ
0.01кΩ
0.1Vrms
1%+5
0.5%+5
1%+5
1%+5
Parallel