E N
Nome file:
File name:
7526006 - ISTRUZIONI SP3600
Rev. 1 05/03/2013
18-40
7. Routine, scheduled and extraordinary maintenance.
Before beginning any work, remember to unplug the
electrical plug
from the
electrical socket.
Do not lubricate and/or use detergents and/or chemical products to clean the product.
All extraordinary maintenance (replacement of supply cord
,
etc.) must be carried out by specialised technicians.
Replace any damaged and/or worn components as quickly as possible; use only original spare parts. For this purpose, please consult the “Retail and spare parts
and relevant documentation”.
For regular control:
Check that the mechanical parts are tightly secured and check the condition of the screws supporting the product.
Check that the power cord and isolating parts are in their correct position, are secure and in a good state of repair.
Check the temperature of the product and the electric motor. In the event of a fault, stop the product immediately and contact specialised technicians.
Check for product vibrations. In the event of a fault, stop the machine immediately and contact specialised technicians.
7.1. Routine maintenance.
To be performed at least once a year, or more frequently if necessary.
Product components that, due to their normal use, suffer wear and/or tear must be regularly replaced to ensure good product performance. The following table
shows the perishables and/or consumables used in the product and their estimated working life.
O rings and general seals
1 year
Mechanical seal
1 year
Tab. 6
7.2. Extraordinary maintenance.
Extraordinary product maintenance must be performed by a specialised technicians.
This consists in replacing worn or damaged parts (power cord,
bearing
,
rotor
,
impeller,
etc.).
8. Troubleshooting.
PROBLEM
POSSIBLE CAUSE
1
ST
SOLUTION
2
ND
SOLUTION
1. The product does not work.
No or insufficient power supply.
Check the power supply.
Contact specialised technicians.
2. The product does not work.
The
power plug
is not correctly
inserted in the
power outlet
.
Firmly insert the
power plug
in the
power outlet.
Contact specialised technicians.
3. The product does not work.
The vent is clogged by dirt, Fig. 17.
Clean the vent.
Contact specialised technicians.
4. The product does not work.
Hydraulic components
clogged or
bent.
Clean and adjust
hydraulic
components
.
Contact specialised technicians.
5. Power cord damaged.
Wear and/or negligence.
Contact specialised technicians.
-
6. Plastic components damaged.
Wear.
Replace.
Contact specialised technicians.
7. Low
flowrate
from
outlet
The product is dirty
Clean the product.
Contact specialised technicians.
8. Low
flowrate
from
outlet
Hydraulic components
clogged or
bent.
Clean and adjust
hydraulic
components
.
Contact specialised technicians.
9. Low
flowrate
from
outlet
The
impeller’s
blades are worn out.
Replace the
impeller.
Contact specialised technicians.
10. Low
flowrate
from
outlet
The product is not trimmer correctly.
Trime the product like illustrated in
Fig. 16.
Contact specialised technicians.
11. The product does not work.
The
thermal protector
has been
triggered.
Check that the water temperature
does not 35 [°C] and, if
necessary, add cold water to the
pool
to lower water temperature.
Contact specialised technicians.
12. The product does not work.
The
thermal protector
has been
triggered.
Blocked drive shaft, follow the
instructions in Blocked
rotor
.
Contact specialised technicians.
13. The product does not work.
The
bearing
are worn out.
Replace the
bearing
Contact specialised technicians.
14. Water leak.
Gaskets or o-rings incorrectly
installed
Check correct gasket and o-ring
installation, see Fig. 19, # 1, 2, 3, 4,
5.
Contact specialised technicians.
15. Loss of water from
mechanical
seal
.
A
mechanical seal
is used to isolate
the
pump
body and the motor body.
Some drops of water may flow out
once in a while this is normal,
especially after periods of non use.
If the leaks are consistent Please
contact specialised technicians..
-
16. Blocked
rotor
.
Foreign bodies block the rotating
elements of the product (
impeller
or
cooling fan).
Remove any foreign bodies.
Contact specialised technicians.
17. Blocked
rotor
.
Blocked drive shaft, it can happen
after a long period of inactivity.
Do the following:
1.
unplug the product from the
power outlet
;
2.
make the drive shaft turn 9-
10 times, using a
screwdriver as shown in
Fig. 18;
3.
insert the
power plug
of the
product into the
power
outlet.
Contact specialised technicians.
Tab. 7
9. Retail and spare parts and relevant documentation.
See Tab. 3 with reference to Fig. 19.
Replace any damaged and/or worn components as quickly as possible; use only original spare parts.