- 19 -
7.
1)
Inspect the battery fluid level. If it is near the lower
level, add distilled water until it reaches the upper
level.
2)
Inspect for loose terminals and retighten if loose.
<Note>
It is necessary to recharge the battery when the
specific gravity of the battery fluid is 1.23 or less.
Contact the retail outlet where the equipment was
purchased if this occurs.
Battery Replacement Procedures
1)
Remove the "
-
" (negative) cable.
(Always be sure to first remove the "
-
" (negative)
side.)
2)
Remove the battery hold-down clamp.
3)
Remove the
“+” (positive) cable.
4)
Remove the battery.
* Install the battery by performing the above
procedures in reverse order.
(Always be sure to first attach the "+" (positive)
side.)
<Note>
Use the specified battery.< 46B24L > (Japanese Industrial Standard)
8. Operating Procedures
Warning: Suffocation from Exhaust Fume
Do not operate the equipment in a poorly-ventilated area such as indoors or within a
tunnel because the engine exhaust fume includes components that are harmful to
humans.
Warning: Fire
Keep any ignitable items (such as fuel, gas and paint) or inflammable items away
from the equipment because the muffler, exhaust fume and other parts attain high
temperatures.
Provide at least 1 meter (3 feet) of distance between the equipment and walls and
other obstacles, and operate the equipment on a flat surface.
Caution: Suffocation from Exhaust Fume
Do not direct the engine exhaust towards passersby, private homes or similar
persons/locations because the engine exhaust fume includes components that are
harmful to humans.
Caution: Burn
The engine, muffler and similar parts are extremely hot during operation and
immediately after stopping the equipment. Never touch hot parts.
Caution: Injury
Use this equipment with it situated on a stable level surface so that it is prevented
from moving.
Do not move the equipment during operation.
Always be sure to turn off the switches of all devices using the equipment and turn
off the equipment breakers before starting the engine.
[
+]Post
Hold-Down Clamp
[
–]Post
Battery
Terminal
UPPER
LEVEL
LOWER
LEVEL