![Shindaiwa DGW400DMK Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/shindaiwa/dgw400dmk/dgw400dmk_owners-and-operators-manual_1257617014.webp)
- 11 -
(3) Arc Control (for CC mode)
The equipment includes an arc control function that adjusts
the arc strength.
You can adjust the setting of the short-circuit current of the
weld output by turning the arc control dial.
<Note>
The arc control function is only for "CC" mode. It does not
function if using "CV" or "DROOP".
Always turn the arc control dial to "0"(zero) when the scratch start TIG welding is
functioned otherwise a welding current becomes unstable as the arc control is
functioned.
5-4. Remote Control Receptacle
You can connect the remote controller to the
remote control receptacles to enable remote
operation of weld output adjustment.
<Note>
The output control dial of the remote controller
connection side on the equipment does not
function when a remote controller is
connected.
If the remote controller is removed from the
remote control receptacles while welding, the
equipment output control dial becomes
functional, possibly resulting in a sudden
increase or decrease in weld output.
Do not connect the remote controller plug to the receptacle of an extension cord that
is connected to AC power source. Improper connection causes the caution lamp of
the remote controller to light up indicating a fault.
Do not connect the receptacle of an extension cord used for the remote control to any
other device besides the remote controller.
Set the breaker to "ON" if the cord reel is equipped with one.
5-5. Meter
The equipment includes a DC meter that provides digital display of both weld current
and voltage, and an AC meter that provides digital display of voltage, current and
frequency of single phase 110/115V generated output.
(1) DC Ammeter
– Voltmeter
The DC ammeter and voltmeter display the weld
output for both outputs A and B separately.
If the single/dual selector is set to "SINGLE", the DC
meter for output B does not display current or
voltage.
<Note>
If the weld mode selector is set to "CV", the set
voltage that has been pre-set using the output
control dial is displayed by the voltmeter when not
welding. (The DC ammeter display is blank when
not welding.)
If the weld mode selector is set to "DROOP" or "CC", the set current that has been
pre-set using the output control dial is displayed by the DC ammeter when not welding.
(The voltmeter display is blank when not welding.)
During welding, both the DC ammeter and voltmeter display the actual output values.
When welding is completed, both meters display the actual output values for
approximately 8 seconds, after which display returns to the pre-set values.
Arc Control Dial
Weaker
Stronger
DC Meter
Single/Dual Selector
Remote Controller
(Option)
Caution
Lamp
Remote Control Receptacle
Connect directly or
use an extension cord.
Содержание DGW400DMK
Страница 2: ......
Страница 41: ... 38 15 Engine Wiring Diagram ...
Страница 42: ... 39 16 Generator Wiring Diagram P 1 2 ...
Страница 43: ... 40 P 2 2 ...
Страница 44: ... 41 MEMO ...
Страница 45: ... 42 MEMO ...
Страница 46: ... 43 MEMO ...
Страница 47: ... 44 ...
Страница 48: ... 45 2015 ...