6.  Summary of Convenient Functions 

For trial run and maintenance/inspection and in emergency, automatic operation is released and 

manual position control is enabled.

For trial run and maintenance/inspection or in an emergency, operation can be suspended 

(stand-by or waiting action).  Then, the STBY lamp (green) on the front panel lights and control 

output stops.

For actions in automatic operation, switching of output characteristics, switching between 

operation and suspension, and position setting can be carried out by external input (no-voltage 

contact or open collector).  In case position setting has been made, the position used during the 

automatic operation is changed to a newly set value.  It takes an ON time of 0.2 seconds or 

longer for external input to become effective.  The following three types of setting modes by 

external input are available:

Three in total are selectable, i.e., switching of output characteristics, switching between 

operation and suspension (stand-by), and position setting.

In the mode used only for position setting, 7 values of position in total are selectable.  In this 

case, external input signals are treated as binary numerals.

3 values of position and one individual setting (switching of output characteristics, switching 

between operation/suspension (stand-by) or position setting) are selectable.

The position of the full closing and the opening of the control motor and the like are adjustable. 

Adjustments must be made before the testing operation.

Of the 9 functions; position higher/lower limit absolute value alarms, input from controller 

higher/lower limit absolute value alarms, automatic operation, manual operation, occurrence of 

position error, occurrence of error of input from controller error and control loop trouble; three 

can be selected as events (auxiliary output signals) for contact output.

A motor action which is safe enough at the time of a position error (error of electric potential 

input from control motor) or an input error (error of input signal from controller) can be set.

Selectable from 3 types: Suspension (stand-by action), closing and opening of motor by setting 

its action time.

Selectable from suspension (stand-by action) and setting of position (0~100%). 

   

The output of the position or the control input can be done.

Scaling (reverse scaling) is possible.

Communication setting is possible.  For details, please refer to the communication instruction 

manual.

To remove the noise content of input signals sent from controller.

To position output 0 to 100%, scaling (changing higher limit and/or lower limit) control output 

signal can be done freely in a range from - 10 to 110%. 

To control input signal 0 to 100%, scaling (changing higher limit and/or lower limit) control 

output signal can be done freely in a range from - 10 to 110%. 

Not effective during manual operation.  This is the function to make limiters (limitation) work 

on higher and lower limits of opening.  The function is used, for example, to avoid full opening 

or full closing.

In the case of combined output of SSR and contact, the motor speed can be adjusted by 

controlling ON time and OFF time of operating output to the motor during automatic operation.

Control is carried out by opening/closing operation of the position, using the square of input as 

a target position value.

Keylock means to lock keys so they cannot work when pressed.  There are four selectable types 

of keylock: Without keylock; keylock of screen groups 1 and 2; all keylock except manual 

operation; and all keylock. 

Function

Page

Summary

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Switching between

run/stand-by

Event (option)

External operation

1)    Individual 3 points

2)   7 values of position

3)   3 values of position

and individual 1 point

Position at the time 

of error

1) In the case of position

error

2) In the case of input 

 error

Communication

(option)

Input filter

Input scaling

Position scaling

Position limiter

Moter speed adjustment

Square root extraction

function (option)

Keylock

Zero Span Adjustment

Analog Output (Option)

10

10

12

13

13

14

15

16

16

16

17

17

18

18

18

18

18

19

19

Manual operation

Содержание EM70

Страница 1: ...alog Output Type 17 9 Communication Setting 17 10 Input Range Setting 18 11 Input Filter Setting 18 12 Setting of Input Scaling Position Scaling 18 13 Position Limiter Setting 18 14 Motor Action Time...

Страница 2: ...The alert mark on the plate affixed to the instrument On the terminal nameplate affixed to the case of this instrument the alert mark is printed This is to warn you of the risk of electric shock whic...

Страница 3: ...5 16 17 OPEN 2A240VAC CLOSE COM 2A240VAC M3 M2 M1 SSR 26 TERMINAL 1 SPECIFICATION 27 28 SG SD RD SG RS 232C RS 485 Follow 3 5 Terminal Layout and 3 6 Terminal Arrangement Table and make sure to conduc...

Страница 4: ...iring is shown Particular attention should be paid to common lines and polarity INPUT DC Power supply for motor Power supply for EM70 100 240V AC 50 60Hz L N CW CW Clockwise CCW Counterclockwise Poten...

Страница 5: ...changes the display in the following order Position value input value target position value deviation value position value Display returns to the initial screen of a screen group such as 1 0 or 1 00 z...

Страница 6: ...e direction of revolution involves danger Correct the wiring if that is the case with reference to Cause of Trouble and Troubleshooting You should also confirm the positions of the control motor in th...

Страница 7: ...al input from control motor or an input error error of input signal from controller can be set Selectable from 3 types Suspension stand by action closing and opening of motor by setting its action tim...

Страница 8: ...md EXE Value of position 7 Value of position 6 0 50 0 51 0 60 0 70 Individual 3 points setting 7 values of position setting 3 values of position and individual 1 point setting Individual setting Valu...

Страница 9: ...tment Event 1 type setting Manual adjustment 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 13 1 14 1 15 1 16 1 17 1 25 1 26 1 27 1 28 1 00 1 Span side manual adjustment 1 00 2 The 1 0 zero span automatic adjustme...

Страница 10: ...ghts DISP DISP DISP DISP 0 0 Basic screen Present position value is displayed in 0 0 1 Control input value display screen Control input is displayed in 0 0 2 Target position value display screen Targe...

Страница 11: ...events allowing event set values to be set i e higher and lower limits of position and higher and lower limits of inputs as shown below 4 types of alarms Lower limit of position Higher limit of posit...

Страница 12: ...individually 7 preset position values are set for DI1 DI2 and DI3 3 preset position values are set for DI1 and DI2 and for DI3 one is selected from no rA St and Pr About DI type action and setting ra...

Страница 13: ...n to allow you to set only when Pr is selected as the value of position on the 0 51 052 and 0 53 external operating input screen 7 Setting of 7 point External Operating Input Position Value Initial va...

Страница 14: ...g range 0 100 7 4 Screen group 1 and parameter setting There are various apparatus that have relation to the settings in screen group 1 Please have a person who is familiar with the apparatus conduct...

Страница 15: ...justment screen which blinks while adjustment is going on 2 Set the motor to the zero position usually full close by the use of and keys When the key is pressed for registration the display changes to...

Страница 16: ...7 screen Event 3 type setting screen Initial value The same as event 1 Event 3 hysteresis setting screen Initial value 0 1 Setting range 0 1 5 0 The same as event 1 Event 3 stand by action setting scr...

Страница 17: ...except manual operation Communication address setting screen Initial value 1 Setting range 1 99 In case a plurality of controllers are linked for communication addresses need to be set individually to...

Страница 18: ...ling lower limit setting screen Initial value 0 Setting range 10 109 lower limit higher limit 100 0 20 80 100 Input scaling n o i t i s o P n o i t i s o P Input 100 75 15 0 0 1 0 Position scaling Inp...

Страница 19: ...ue Keylock of screen groups 1 and 2 All keylock except manual operation All keylock In case manual operation is set before setting keylock however operation by and keys is possible 1 38 Key Operation...

Страница 20: ...occur simultaneously the position error is given preference and the control loop error check is released Refer to the following formula in setting the control loop error detection time Set value of c...

Страница 21: ...iometer of control motor or for control signals Erroneous setting of output characteristic DA RA Correct wiring to potentiometer of control motor terminals 4 5 and 6 or for control signals terminals 1...

Страница 22: ...on of control loop error to a somewhat larger value Input higher limit error Control input signal exceeds higher limit 110 in HH Mismatch between input range and control input signal Problem with inpu...

Страница 23: ...3 type setting Event 3 hysteresis Event 3 stand by action Control at the time of position error Opening closing time at the time of position error Control at the time of input error Opening closing t...

Страница 24: ...n values and individual assignment to one of RA STBY and preset position value is possible z Operation Put in action when no voltage contact or open collector turns ON Event output option z Number of...

Отзывы: