Name

Function

Position display (green)

(1)  The present position is shown by a percentage (0 to100%) of opening in the form of bar graph.  
 (green)
(2)  The bar graph displays 20 dot (resolution of 5%).  Lights when position value goes above 2.5%,  

lights full when above 97.5%.  Turns off when below 2% with 0.5% of hysteresis. 

(1)  Position (degree of opening) is displayed usually but display changes every pressing of the             

key from INPUT to DES (set value of position) and to DEV (deviation).  (Position, input, target 

degree of position and deviation displays) (green)

(2)  Set value and item are displayed on each parameter screen.

Data display (green)

(1)  POSITION (green) lights when display of present position is selected.
(2)  INPUT (green) lights when control input display is selected.
(3)  DES/DEV (green) lights when target position display or deviation display is selected. 
(4)  EV1 (orange) lights when Event 1 is in action.
(5)  EV2 (orange) lights when Event 2 is in action.
(6)  EV3 (orange) lights when Event 3 is in action.
(7)  DI1 (green) lights when external input (DI1) is ON.
(8)  DI2 (green) lights when external input (DI2) is ON.
(9)  DI3 (green) lights when external input (DI3) is ON.
(10)  MAN (green) flashes during manual operation and remains off during automatic operation.
(11)  RA (green) lights during reverse action (RA) and remains off during direct action (DA).
(12)  STBY (green) lights when stand-by is selected in operation/suspension switching.  It remains off 

during ordinary operation.

(13)  COM (green) lights when COM (reading/writing) is selected for communication and goes out when 

LOC (reading) is selected.

(14)  OPEN (green) lights when opening control output (OPEN) is ON.  Conducting across terminals M1 

and M2.

(15) CLOSE (green) lights when closing control output (CLOSE) is ON.  Conducting across terminals 

M2 and M3.

(1)            (display) key

While the EM70 is in ordinary operation, this key is used to change the display. Each pressing 

of it changes the display in the following order: Position value 

input value 

 target position 

value 

deviation value 

 position value.

Display returns to the initial screen of a screen group, such as "1-0 or 1-00 zero span 

adjustment screen" in screen group 1 or "2-0 screen for setting delay time on occurrence of 

position error" in screen group 2.  From the initial screens of screen groups 1 and 2, it returns 

to "0-0 basic screen."

(2) 

  (parameter) key 
Used to proceed from a parameter setting screen to the next parameter setting screen.
By pressing this key continuously for 3 seconds on "the 0-0 basic screen," you can proceed to 

"The 1-0 or 1-00 Zero span adjustment screen."

(3)            (down) key

Used to decrease a numerical value on a numerical value setting screen.
Used to select an item on a screen for selection.

 During manual operation (MANUAL), closing control output (CLOSE) turns ON.

(4)            (up) key

Used to increase a numerical value on a numerical value setting screen.

 

Used to select an item on a screen for selection.

 During manual operation (MANUAL), opening control output (OPEN) turns ON.

(5)          (entry/registration) key

On each parameter screen, a value set or an item selected by means of the            or            key 

is registered by pressing this key.

When pressed continuously for 3 seconds on "1-0 zero/span automatic control screen,"

automatic span adjustment is carried out.

 

When pressed continuously for 3 seconds on "1-00 zero/span automatic control screen," the

display changes to the zero manual adjustment screen.

(6)           (manual/automatic) key

Pressing this key on "the 0-0 basic screen" continuously for 2 seconds changes automatic 

operation to manual operation. (This can be done alternatively by pressing the            key and 

the            key simultaneously.)

 

When pressed continuously for 2 seconds in manual operation (MANUAL), manual operation 

(MANUAL) is released to return to automatic operation (AUTO).
By pressing this key on a setting screen of the screen group 1, you can go back to the screen 

preceding it.

Action display lamps

Operating keys

D I SP

D I SP

ENT

ENT

AUTO

MAN

AUTO

MAN

1

1

1

1

2

2

2

2

1

1

1

2

2

2

3

3

3

3

3

4

Содержание EM70

Страница 1: ...alog Output Type 17 9 Communication Setting 17 10 Input Range Setting 18 11 Input Filter Setting 18 12 Setting of Input Scaling Position Scaling 18 13 Position Limiter Setting 18 14 Motor Action Time...

Страница 2: ...The alert mark on the plate affixed to the instrument On the terminal nameplate affixed to the case of this instrument the alert mark is printed This is to warn you of the risk of electric shock whic...

Страница 3: ...5 16 17 OPEN 2A240VAC CLOSE COM 2A240VAC M3 M2 M1 SSR 26 TERMINAL 1 SPECIFICATION 27 28 SG SD RD SG RS 232C RS 485 Follow 3 5 Terminal Layout and 3 6 Terminal Arrangement Table and make sure to conduc...

Страница 4: ...iring is shown Particular attention should be paid to common lines and polarity INPUT DC Power supply for motor Power supply for EM70 100 240V AC 50 60Hz L N CW CW Clockwise CCW Counterclockwise Poten...

Страница 5: ...changes the display in the following order Position value input value target position value deviation value position value Display returns to the initial screen of a screen group such as 1 0 or 1 00 z...

Страница 6: ...e direction of revolution involves danger Correct the wiring if that is the case with reference to Cause of Trouble and Troubleshooting You should also confirm the positions of the control motor in th...

Страница 7: ...al input from control motor or an input error error of input signal from controller can be set Selectable from 3 types Suspension stand by action closing and opening of motor by setting its action tim...

Страница 8: ...md EXE Value of position 7 Value of position 6 0 50 0 51 0 60 0 70 Individual 3 points setting 7 values of position setting 3 values of position and individual 1 point setting Individual setting Valu...

Страница 9: ...tment Event 1 type setting Manual adjustment 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 13 1 14 1 15 1 16 1 17 1 25 1 26 1 27 1 28 1 00 1 Span side manual adjustment 1 00 2 The 1 0 zero span automatic adjustme...

Страница 10: ...ghts DISP DISP DISP DISP 0 0 Basic screen Present position value is displayed in 0 0 1 Control input value display screen Control input is displayed in 0 0 2 Target position value display screen Targe...

Страница 11: ...events allowing event set values to be set i e higher and lower limits of position and higher and lower limits of inputs as shown below 4 types of alarms Lower limit of position Higher limit of posit...

Страница 12: ...individually 7 preset position values are set for DI1 DI2 and DI3 3 preset position values are set for DI1 and DI2 and for DI3 one is selected from no rA St and Pr About DI type action and setting ra...

Страница 13: ...n to allow you to set only when Pr is selected as the value of position on the 0 51 052 and 0 53 external operating input screen 7 Setting of 7 point External Operating Input Position Value Initial va...

Страница 14: ...g range 0 100 7 4 Screen group 1 and parameter setting There are various apparatus that have relation to the settings in screen group 1 Please have a person who is familiar with the apparatus conduct...

Страница 15: ...justment screen which blinks while adjustment is going on 2 Set the motor to the zero position usually full close by the use of and keys When the key is pressed for registration the display changes to...

Страница 16: ...7 screen Event 3 type setting screen Initial value The same as event 1 Event 3 hysteresis setting screen Initial value 0 1 Setting range 0 1 5 0 The same as event 1 Event 3 stand by action setting scr...

Страница 17: ...except manual operation Communication address setting screen Initial value 1 Setting range 1 99 In case a plurality of controllers are linked for communication addresses need to be set individually to...

Страница 18: ...ling lower limit setting screen Initial value 0 Setting range 10 109 lower limit higher limit 100 0 20 80 100 Input scaling n o i t i s o P n o i t i s o P Input 100 75 15 0 0 1 0 Position scaling Inp...

Страница 19: ...ue Keylock of screen groups 1 and 2 All keylock except manual operation All keylock In case manual operation is set before setting keylock however operation by and keys is possible 1 38 Key Operation...

Страница 20: ...occur simultaneously the position error is given preference and the control loop error check is released Refer to the following formula in setting the control loop error detection time Set value of c...

Страница 21: ...iometer of control motor or for control signals Erroneous setting of output characteristic DA RA Correct wiring to potentiometer of control motor terminals 4 5 and 6 or for control signals terminals 1...

Страница 22: ...on of control loop error to a somewhat larger value Input higher limit error Control input signal exceeds higher limit 110 in HH Mismatch between input range and control input signal Problem with inpu...

Страница 23: ...3 type setting Event 3 hysteresis Event 3 stand by action Control at the time of position error Opening closing time at the time of position error Control at the time of input error Opening closing t...

Страница 24: ...n values and individual assignment to one of RA STBY and preset position value is possible z Operation Put in action when no voltage contact or open collector turns ON Event output option z Number of...

Отзывы: