- 3 -
Where the instrument is exposed to dew drops or direct
sunlight.
Where the height is above 2000 m.
Outdoors.
Note:
The environmental conditions belong to the installation
category II of IEC60664 and the degree of pollution is II.
3-2. Mounting
For safety's sake and to protect the functionality of the product,
do not remove its body from the case. If it needs to be drawn
out for replacement or repair, call our sales office in your
neighborhood.
3-3. Wiring
z
When wiring, make sure to disconnect the power supply.
Otherwise an electric shock may result.
Make sure to ground the protective conductor terminal ( ).
Otherwise you may receive an electric shock.
z
After wiring, do not touch terminals or other charged elements
while it is energized. Otherwise an electric shock may result.
3-4. External Dimensions and Panel Cutout
96
Panel cutout
11
100
96
111
91.6
92
92
130 or wider
Unit: mm
+0.8
0
+0.8
0
130 or wider
D I SP
CLOSE
AUTO
MAN
OPEN
ENT
DATA DISPLAY
POSITION INDICATOR
MAN
DES/DEV
EV2
EV1
POSITION
INPUT
0
DI1
EV3
DI3
DI2
20
40
60
SERVO controller
CLOSE
STBY
RA
COM
100%
80
OPEN
EM70
3-5. Terminal Layout
1
2
3
4
5
6
7
8
9
10
21
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
28
29
30
DC
R2
COM
DI3
DI2
DI1
COM
OPEN
EV3
EV2
EV1
F.B.POT.
100-2K
1A240VAC
1A240VAC
1A240VAC
2A240VAC
CLOSE
COM
2A240VAC
A-output
4-20mA DC
100-240VAC~
50/60Hz 13VA
R1
OPEN
CLOSE
R3
M3
M2
M1
INPUT
–
+
+
L
N
–
*1
15
16
17
OPEN
2A240VAC
CLOSE
COM
2A240VAC
M3
M2
M1
SSR
26
TERMINAL
*1
SPECIFICATION
27
28
SG
SD
RD
SG
RS-232C
RS-485
+
–
Follow 3-5 Terminal Layout and 3-6 Terminal Arrangement
Table and make sure to conduct wiring correctly.
The press-fit terminal must fit an M3.5 screw and have a
width of 7 mm or smaller.
The input signal wire must not be accommodated with a
high-voltage power cable in the same wiring conduit or duct.
Shielded wire (one-point grounding) is effective to avoid
electrostatic induction noise.
Twisting the input wires at short and equal intervals is an
effective way to avoid magnetic induction noise.
For wiring for power supply, use a 600V vinyl insulated wire
or cable which is 1 mm2 or larger in section or a wire or cable
of equivalent for higher performance.
The wire for grounding must be 2 mm2 or larger in section
and must be grounded at a grounding resistance of 100
ȍ
or
lower.
Clamp the terminal screws firmly.
Clamp receiving torque: 1.0N.m (10 kgf.cm)
&RXQWHUPHDVXUH
against lightning surge will be required for
signal line over 30m.
Cut a hole for mounting the controller in the panel by
referring to the cutout drawing in Section 3-4.
The panel thickness should be 1.0 ~ 4.0 mm.
As the instrument is provided with pawls for fixing, just press
it firmly from the front of the panel.
The EM70 is designed to be mounted on a panel. Never use it
without mounting on the panel.
Be sure to install this product with the attached gasket.
Failure to do so could result in electric shock.
,QFDVHLIWKH
JDVNHWLVEURNHQRUIDOOVRIISOHDVHUHSODFHLWZLWKWKH
GHVLJQDWHGRQH