Car security systems
45
45
45
45
condition of automatic box.
�
Turning of turbo timer off is confirmed by two short audio signals.
Attention!
Attention!
Attention!
Attention!
Condition of turbo timer is maintained by all lines of ignition IGN1, IGN2 and IGN3.
Remote
Remote
Remote
Remote control
control
control
control over
over
over
over supplementary
supplementary
supplementary
supplementary equipment
equipment
equipment
equipment (channel
(channel
(channel
(channel CH6)
CH6)
CH6)
CH6) –
–
–
– function
function
function
function SF14
SF14
SF14
SF14 (detour
(detour
(detour
(detour of
of
of
of
rated
rated
rated
rated system)
system)
system)
system)
The system has channel CH6 (wire – light blue with green) of control over different supplementary equipments,
which connecting to system.
The channel may use (program) how:
�
Pulsed output of negative polarity.
All times are activated until system accomplishes the procedure of
automatic start and the engine works under the control ZX-1060.
Turning off the emergency protection
abolishes action of pulse at any time.
�
Pulsed output of negative polarity.
At turning on of line ING1 is activated temporarily, before finish of
rolling of starter (until the engine is not started).
�
1 second pulsed output of negative polarity.
At turning off of line ING1 of system of auto run is activated or
at turning off of ignition by the key.
�
One second pulsed output of negative polarity.
At turning of ignition on is activated in condition of start of
the engine by system of auto run ZX-1060.
Output of channel CH6 – is connected with “mass” during time of activation of channel.
Output of channel CH6
weak current output which is preassigned for control over winding of supplementary relay or equivalent weak
current loading.
Programmable
Programmable
Programmable
Programmable function
function
function
function of
of
of
of remote
remote
remote
remote start
start
start
start of
of
of
of system
system
system
system
Output
Output
Output
Output to
to
to
to condition
condition
condition
condition of
of
of
of program
program
program
program
�
Divest the system out of the protection by means of trinket-transmitter or button “Valet”.
�
Install the switch “AST” to condition “is turned off” (“OFF”).
�
Turn on the ignition.
�
During 5 seconds switch “AST”ON/OFF 3 times. You can hear one short signal of siren.
�
During 5 seconds turn off, afterwards turn on the ignition. You enter to condition of programmable function
SF1 automatically. LED begins to blink by single flashes.
In condition of program one or another of function the amount of flashes LED corresponds number of
programmable function, 1 and 2 and so on signals of siren indicate condition of that function.
After signals of siren You can:
�
Change the condition of that function (pressed the button 1 of trinket-transmitter).
Herewith You again can
hear 1, 2, 3, 4 or 5 signals of siren correspondingly to new condition of function.
�
Transfer to following function (switched the switch “AST”ON/OFF.
�
Leave the condition of program (for example, turned off the ignition).
Remark
Remark
Remark
Remark
Do not admit that among Your actions more 10 seconds went, otherwise, system leaves the condition of program
automatically, and You can hear 1 short and 1 long signal of siren.