TROUBLESHOOTING
Symptoms
Check here
The product does not
operate
(Movements are
strange)
Operation time is
shorter.
was pressed but
the operation does not
stop immediately.
Abnormal sound is
emitted.
The suction power
becomes weak during
operation in the "High
mode".
The suction power is
weak.
The product stops
during operations.
Filter care lamp (red)
blinks rapidly.
The operating sound
changed or became
louder.
The battery cannot be
charged.
(The Charging lamp
(red) of the charger is
not turned on)
The battery cannot be
charged.
(The Charging lamp
(red) of the charger
blinks rapidly)
The Charging lamp
(red) of the charger
blinks slowly)
Contact your nearest service center approved by SHARP if the product still stops during cleaning even
if the measures described above have been implemented.
Filter care lamp (red)
turns on.
Remove the battery from the vacuum cleaner body, wait for about one
minutes to pass and then reinstall the battery on the vacuum cleaner
body and restart the operation.(The vacuum cleaner body circuit
becomes reset and the product is restored to normal operation.)
Is there any dirt or foreign matter trapped between the Pleat filter and the
Mesh filters?
Is the filter of the Dust cup assembly is dirty?
Remove the Dust cup assembly, dispose of dirt and remove the dirt
and dust on the filter.
Is the Suction head blocked? (When cleaning a mat or a enclosed nozzle is
used)
Press the and then restarting operation turns the lamp off.
Is there any clogging on the Mesh filters or Pleat filter?
Clean the filter by rinsing with water.
Is there any dirt clogging the pipe or the Suction head?
Remove the clogging dirt.
There is no malfunction if the product blinks slowly in an environment
with a low temperature (about 5°C or lower) or a high temperature
(about 35°C or higher). Charge the battery in an environment that is
between 5°C to 35°C.
Is there any dirt or foreign matter attached to a terminal of the charger
or the battery?
Remove the dirt or foreign matter with dry cloth.
If the slow blinking occurs when the room temperature is between 5°C and
35°C, then it is time to replace the battery. Replace the battery.
The symptom may be caused by malfunction of the charger,deterioration
or malfunction of the battery.
Contact your nearest service center approved by SHARP.
(Leaving a battery without charging and depleted for a prolonged period of
time can deteriorate the battery, which may need to be replaced.)
Continuously performing power operation at a location exposed to
direct sun light or in an environment with high temperature such as
inside a car parked under the flaming sun and the like can
automatically reduce the suction power as the overheating
protection circuit is triggered to prevent deterioration of the battery.
The motor keeps on turning for a while even after the is pressed,
but this is not a malfunction.
The operating time gradually becomes shorter as the battery is used
repeatedly.Replace the battery when the operating time is extremely
short even when the battery has been charged.
Is the battery correctly set to the vacuum cleaner body?
Is the Dust cup assembly correctly installed on the vacuum cleaner body?
Is there any large dirt such as a piece of tissue paper entangled inside the
Dust Cup?
Is there much dirt accumulating in the Dust Cup?
Is the charge remaining in the battery low? Charge the battery.
Is the battery correctly set to the charger?
Is the power plug of the charger securely inserted in the power outlet?
Is the vacuum cleaner body overheating? Leave the product in a cool
place for a while.
Is there any clogging on the Mesh filters or Pleat filter?
Clean the filter by rinsing with water.
Is the charge remaining in the battery low? Charge the battery.
Details on the types of matters that must be observed
are explained using following symbols.
Do not do this
Must do this
When product is used
When product is used
Charger
Matters for preventing electrocution,
fire disaster and malfunction of
vacuum cleaner body
(Risk of deformation of vacuum
cleaner body, ignition of fire
and fire disaster due to
overheating.)
(Risk of electrocution and
malfunction of product.)
(Risk of injury or malfunction of product
when the vacuum cleaner body becomes
dislodged or falls.)
(Risk of electrocution, electric current leakage and
fire disaster due to deterioration of insulation.)
(Risk of electrocution or injury.)
(Risk of injury of a hand or the like.)
Be particularly careful with children!
(Risk of heating, ignition of fire, electrocution or
product malfunction.)
(Risk of fire disaster, electrocution or injury.)
Contact your nearest service center approved by
SHARP.
(Risk of burns.)
Disconnect the power cord of the charger
from the electrical outlet.
Press the and remove the battery
from the vacuum cleaner body.
(Risk of electrocution, short circuiting and ignition
of fire.)
Do not operate the product over a
long period of time with the Suction
head blocked.
Do not allow any metal objects or pins to
enter in the pipe insertion slots, pipe
contacts or air exhaust port.
Do not transport the product by
holding on a pipe or the Dust Cup.
Disconnect the power cord of the product
from the electrical outlet when not using
the product over a long period of time.
Must do the followings when servicing
or inspecting the product
Do not touch the Rotary Brush or Roller
Switch (with safety stop mechanism).
Do not touch the terminals of the vacuum
cleaner body, the charger or the battery with
a metal object such as a needle or a pin.
Do not touch the terminals of the charger
or the battery while charging or
immediately after completing charging.
Never modify the structure of the vacuum
cleaner body or the charger and do not
disassemble and no one must repair the
product unless the individual is a repair
technician.
Be sure to remove the power plug from
the power outlet by holding onto the
power plug with a hand.
Do not block the air exhaust port
Pipe contact
Roller
Switch
Rotary
brush
Problems with vacuum cleaner body during operation
Charging
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the Cord of the Charger is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The Suction head and Pipe (accessories) are only to be used with the appliance. Do not connect these accessories with
the power outlet or plug, socket-outlet, connector or appliance inlet that is connected with the power outlet.
ENGLISH
EC-A1RHK_A4(W page imposition).indd 5-6
2018/12/06 14:26:57