AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 31
Operation/procedure
The operation status of the sensors and detectors in the original size
detection section are displayed. The active sensors and detectors are
highlighted.
For AB series, PD1 to 5 is displayed, for inch series, PD1 to 4.
Operation/procedure
Place an A3 (or WLT) document on the document table, and press
[START] key with the OC cover open.
The adjustment is performed and the result is displayed.
The value in [ ] shows the threshold value. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution of the simulation, “EXECUTING” is displayed.
Operation/procedure
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
Operation/procedure
Set the OC cover at 20 degrees detection and press the [START] key.
The detection output level of each sensor is displayed in real time.
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution, [EXECUTING] is highlighted.
41
41-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the document size detection photo
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
PD1 to 5
Original sensor status
Without original: Normal display
With original: Highlighted display
41-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the detection level of the document size
photo sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
41-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the light reception level and the
detection level of the original size detection photo
sensor.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
41-4
Purpose
Adjustment
Function
(Purpose)
Used to adjust the detection level of OC 20 degrees.
Section
Others
Item
Operation
OCSW
Original cover state
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)