AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 16
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 12 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –380V.
Operation/procedure
1.
Enter the set value with the 10-key.
2.
Press the [START] key.
Output is made with the entered value for 30sec. and the display
returns to the original state.
Min. unit: 25V increment
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 12 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –380V.
Operation/procedure
1.
Select the operation mode with the 10-key.
2.
Press the [START] key.
The operation is performed for 30sec, and the display returns to the
original state.
Operation/procedure
Enter the set value with the 10-key.
When the duplex motor setting is made, the duplex 2motor is also set
accordingly.
8-15
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in FAX mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Setting range
1-12
Default
5
NO.
Set value
Grid High
Grid Low
1
480
–480V
–380V
2
505
–505V
–405V
3
530
–530V
–430V
4
555
–555V
–455V
5
580
–580V
–480V
6
605
–605V
–505V
7
630
–630V
–530V
8
655
–655V
–555V
9
680
–680V
–580V
10
705
–705V
–605V
11
730
–730V
–630V
12
755
–755V
–655V
SIMULATION 8-14
SIMULATION 8-15
9
9-1
Purpose
Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the load
(motor) in the duplex section and the control circuit.
Section
Duplex
Item
Operation
Item
Content
1
DMF145
Duplex motor/Duplex 2 motor forward rotation
(145mm/s)
2
DMF122
Duplex motor/Duplex 2 motor forward rotation
(122mm/s)
3
DMR145
Duplex motor/Duplex 2 motor reverse rotation
(145mm/s)
4
DMR122
Duplex motor/Duplex 2 motor reverse rotation
(122mm/s)
9-4
Purpose
Operation test/check
Function (Purpose)
Duplex motor RPM setting
Section
Duplex
Item
Operation
Setting range
1-13
Default
3
SIMULATION 9-1