AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 27
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the PS expansion kit soft key with the 10-
key and press the [START] key, and the collating result is displayed
with OK or NG.
After canceling the simulation, if OK, the PS expansion kit function is
enable; if NG, the PS expansion kit function is disabled.
This setting must be reset after the simulation cancel.
Note: Executable only when the PCL/PS3 is installed.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Note: Setup is allowed only for Japan and UK.
Operation/procedure
Select the display language (language code) with the 10-key according
to the table below, and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Input the set value with the 10-key and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Enter the set value with 10-key, and press [START] key.
26-14
Purpose
Setting
Function
(Purpose)
Used to input the Software Key for the PS extention kit.
Section
Printer
Item
Specifications
26-18
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of toner save operation.
Item
Specifications
Operation mode (Common)
Item
Content
Setting
range
Default
0
OFF
Disable
0-1
0
1
ON
Enable
26-22
Purpose
Setting
Function
(Purpose)
Used to set the specification (language display) for the
destination.
Item
Specifications
Item
Language
code
ASIC
expression
Remarks
0
JAPANESE
ja
6A 61
1
ENG.US
en
65 6E
2
ENG.UK
gb
67 62
3
FRENCH
fr
66 72
4
GERMAN
de
64 65
5
ITALY
it
69 74
6
DUTCH
nl
6E 6C
7
SWEDISH
sv
73 76
8
SPANISH
es
65 73
9
PORTUGUESE
pt
70 74
10 TURKISH
tr
74
72
11 GREEK
el
65 6C
12 POLISH
pl
70 6C
13 HUNGARIAN
hu
68 75
14 CZECH
cs
63 73
15 RUSSIAN
ru
72 75
16 FINNISH
fi
66 69
17 NORWEGIAN
no
6E 6F
18 DANISH
da
64 61
19 CHINESE
zh
7A 68
20 TAIWANESE
tw
74 77
Traditional Chinese
supported locally
21 SLOVAK
sk
73 6B
22 HEBREW
he
68 65
Supported locally
23
BRAZILIAN
PORTUGUESE
pb
70 62
24 ARABIC
ar
61 72
26-30
Purpose
Setting
Function
(Purpose)
Used to set ON/OFF of the heater lamp slow-up control
conforming to the CE mark control.
Item
Specifications
Operation mode (Common)
Item
Default
Japan, SEC, SECL, SCA, SEF, Taiwan
Others
0
OFF
0
1
1
ON
26-35
Purpose
Setup
Function
(Purpose)
Used to set whether the same continuous troubles are
displayed as one trouble or the series of troubles with
SIM 22-4 when the same troubles occur continuously.
Item
Specifications
Item
Content
Default
0
ONCE
When two or more troubles occur, only one is
registered.
0
1
ANY
All the troubles occurred are registered.
Item
Language
code
ASIC
expression
Remarks
SIMULATION 26-22