AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 36
Operation/procedure
Enter the set value with the 10-key, and press the [START] key.
Set the toner supply previous rotation time.
Operation/procedure
1.
Touch the item to be adjusted. (Automatic adjustment)
The currently set value is highlighted beside the adjustment item.
2.
Press the [START] key.
The display is shifted to the copy menu.
3.
Select the paper feed tray and the print density.
Use the 10-key to set the exposure level.
4.
Press the [START] key.
Copying is started.
(Exposure mode)
* Except for AE and AE (TS), only Level 3 can be set.
Note: When this simulation is canceled, the display returns to the initial
menu but the machine is not reset.
Operation/procedure
1.
Touch the item to be adjusted.
The adjustment item and the currently set value are highlighted.
2.
Press the [START] key.
The display is shifted to the copy menu.
3.
Select the paper feed tray and the print density.
Use the 10-key to set the exposure level.
4.
Press the [START] key.
Copying is started.
(Exposure mode (Text))
45 +V1 LABEL (122)
122mm/s label paper > LTR
+V1
5-30
5
5
46 +V2 LABEL (122)
122mm/s label paper > LTR
+V2
5-30
12 12
47
+V1 LABEL S
(122)
122mm/s label paper
≤
LTR
+V1
5-30
5
5
48
+V2 LABEL S
(122)
122mm/s label paper
≤
LTR
+V2
5-30
12 12
49 +V1 OHP (122)
122mm/s OHP > LTR +V1
5-30
5
5
50 +V2 OHP (122)
122mm/s OHP > LTR +V2
5-30
8
8
51 +V1 OHP S (122) 122mm/s OHP
≤
LTR +V1
5-30
5
5
52 +V2 OHP S (122) 122mm/s OHP
≤
LTR +V2
5-30
12 12
53
+V1 POSTCARD
(122)
122mm/s postcard/envelope
> 100mm +V1
5-30
5
5
54
+V2 POSTCARD
(122)
122mm/s postcard/envelope
> 100mm +V2
5-30
16 16
55
+V1 POSTCARD
S (122)
122mm/s postcard/envelope
≤
100mm +V1
5-30
5
5
56
+V2 POSTCARD
S (122)
122mm/s postcard/envelope
≤
100mm +V2
5-30
16 16
44-40
Purpose
Setting
Function
(Purpose)
Used to set the time from the start of the main motor
rotation (Ready) to the start of toner supply in previous
rotation after turning on the power.
Setting range
1-99 (sec)
Default
4 (sec)
Item
Content
Setting
range
Default
*1
*2
SIMULATION 44-34
46
46-2
Purpose
Adjustment
Function
(Purpose)
Used to set the exposure level in each exposure mode.
Item
Picture quality
Density
Item
Content
Setting
range
Default
1 AE
AE
1-99
50
2 TEXT
Character
Level 3.0
3 TEXT/PHOTO
Character/Photo
Level 3.0
4 PHOTO
Photo
Level 3.0
5 AE(TS)
AE (TS)
6 TEXT(TS)
Character (TS)
Level 3.0
7 TEXT/PHOTO(TS) Character/Photo (TS) Level 3.0
46-9
Purpose
Adjustment
Function
(Purpose)
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Text).
Item
Picture quality
Density
Item
Content
Setting
range
Default
1 1.0 (SHIFT)
Character level 1.0 (shift q’ty)
1-99
22
2 1.0 (GAMMA)
Character level 1.0 (slant)
1-99
44
3 2.0 (SHIFT)
Character level 2.0 (shift q’ty)
1-99
36
4 2.0 (GAMMA)
Character level 2.0 (slant)
1-99
47
5 3.0 (SHIFT)
Character level 3.0 (shift q’ty)
1-99
50
SIMULATION 46-2