AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 9
H3
11
Content
Sub heater lamp abnormally high
temperature soft detection trouble
Details
A/D value the fusing sub heater lamp
thermistor causes abnormally high
temperature (over 230°C).
Cause
Sub heater lamp thermistor defect.
Control PWB failure.
Fusing section connector contact failure.
Check
and
remedy
Check the sub heater lamp blinking with
SIM 5-2-2.
When the lamp blinks normally:
Check the thermistor and the harness.
Check the MCU PWB thermistor input
circuit.
If lamp lights and stays lit:
Check the power circuit and the lamp
control circuit on MCU PWB.
Clear the display of self-diagnostics with
SIM 14.
H4
00
Content
Main heater lamp abnormally low
temperature detection
Details
The setup temperature (about 90°C) is not
reached within the specified time (about
17sec) from turning on the power.
When the temperature of main heater
lamp thermistor falls below 140°C in the
standby mode or printing.
When the temperature of main heater
lamp thermistor falls below 50°C in the
pre-heat mode.
Cause
Main heater lamp thermistor defect
Main heater lamp failure
Main thermostat failure
Control PWB failure
Check
and
remedy
Check the heater lamp blinking with SIM 5-
2.
When the lamp blinks normally:
Check the thermistor and the harness.
Check the MCU PWB thermistor input
circuit.
If lamp lights and stays lit:
Check for disconnection of the heater lamp
and thermostat.
Check the interlock switch.
Check the power circuit and the lamp
control circuit on MCU PWB.
Clear the display of self-diagnostics with
SIM 14.
Trouble
code
Details of trouble
Main
code
Sub
code
H4
01
Content
Sub heater lamp abnormally low
temperature detection
Details
The setup temperature (about 90°C) is not
reached within the specified time (about
17sec) from turning on the power.
When the temperature of sub heater
thermistor falls below 140°C in the standby
mode or printing.
When the temperature of sub heater lamp
thermistor falls below 50°C in the pre-heat
mode.
Cause
Sub heater lamp thermistor defect.
Sub heater lamp failure.
Sub thermostat failure.
Control PWB failure.
Check
and
remedy
Check the sub heater lamp blinking with
SIM 5-2-2.
When the lamp blinks normally:
Check the thermistor and the harness.
Check the MCU PWB thermistor input
circuit.
If lamp lights and stays lit:
Check the power circuit and the lamp
control circuit on MCU PWB.
Clear the display of self-diagnostics with
SIM 14.
20
Content
Main heater lamp abnormally low
temperature detection
Details
The setup temperature (about –25°C: Sim
43-1-1) is not reached within the specified
time (about 32sec) from turning on the
power.
A/D value of fusing main thermistor is not
reached within the specified temperature.
(specified temperature : SIM43-1 (600dpi)
–25°C )
Cause
Main thermistor defect.
Main heater lamp failure.
Main thermostat failure.
Control PWB failure.
Check
and
remedy
Check the main heater lamp blinking with
SIM 5-1.
When the lamp blinks normally:
Check the thermistor and the harness.
Check the MCU PWB thermistor input
circuit.
If lamp lights and stays lit:
Check the power circuit and the lamp
control circuit on MCU PWB.
Clear the display of self-diagnostics with
SIM 14.
Check that there is no foreign material in
the contact section between the thermistor
and the heat roller.