AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 6
4. Details
Operation/procedure
Enter the number of operations, and set the magnification ratio and the
original size.
1.
Select the desired item, and press the [START] key.
2.
Enter the set value with the 10-key, and press the [START] key.
The scanner unit operates at the speed corresponding to the set value.
The scan counter is displayed during execution.
Operation/procedure
The status of sensors and detectors in the scanner section is dis-
played. The active sensors and detectors are highlighted.
Operation/procedure
Enter the number of operations, and set the magnification ratio and the
original size.
1.
Select the desired item, and press the [START] key.
2.
Enter the set value with the 10-key, and press the [START] key.
The RSPF unit operates at the speed corresponding to the set value.
The scan counter is displayed during execution.
Note: Executable only when the RSPF is installed.
Operation/procedure
The operations of sensors and detectors in the RSPF section are dis-
played.
The active sensors and detectors are highlighted.
(For the original size, the detection result of the original size displayed
on the copy menu is highlighted.)
RSPF width detection size (One of the following is displayed.)
A4/A3, LT/WLT, B5/B4, INV/LTR, A5/A4R, B5R, EXTRA, 8K/16K, 16KR
Note: Executable only when the RSPF is installed.
1
1-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the scanner unit and its
control circuit.
Section
Optical (Image scanning)
Item
Operation
Set magnification ratio
25% to 400% (1% increment)
(Default 100%)
Document size
Varies depending on the destination.
Set number of times
1 to 999 (0: Continuous operation)
1-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensor and detector in
the scanning (read) section and the related circuit.
Section
Optical (Image scanning)
Item
Operation
MHPS
Mirror home position sensor
2
2-1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the RSPF unit and the
related circuit.
Section
RSPF
Item
Operation
Set magnification ratio
50% to 200% (1% increment)
(Default 100%)
Document size
Varies depending on the destination.
Duplex
Selectable only when RSPF is installed.
Set number of times
1 to 999 (0: Continuous operation)
2-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors
in the RSPF unit and the related circuit.
Section
RSPF
Item
Operation
EMPS
Original empty sensor
DLS1
Original length sensor (Small)
DLS2
Original length sensor (Large)
FGOD
RSPF paper feed cover open/close sensor
DFD
RSPF paper entry sensor
RDD
RSPF original exit sensor
OPCLS
Book sensor
SWD_LEN
Original detection width sensor
(Unit of 0.1mm. “Width x 10” is displayed. Example: For
300mm, 3000 is displayed.)
SWD_A/D
Original detection width sensor A/D value