AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 12
Note: In SIM 7-1, pressing [CA] key terminates the simulation and the
machine enters the aging mode without resetting. Therefore, to
perform “4. Intermittent setup,” the intermittent cycle must be set
with SIM 7-6 in advance.
Reset is not performed when the machine enters the aging mode.
Operation/procedure
1.
Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2.
Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Operation/procedure
1.
Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2.
The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3.
After completion of warming up, “WARM UP COMPLETED” is dis-
played and the control returns to the initial screen.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 5V.
The result of (Set value) / 5 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *5)
is used as the set value.
Therefore, a multiple number of 5 must be entered. If not, the value +1
to +4 is displayed after pressing [START] key.
7-6
Purpose
Setting/Operation test/check
Function (Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Setting range
1-255
Default
3
7-8
Purpose
Setting/Operation test/check
Function
(Purpose)
Used to set the display of the warm-up time.
Item
Operation
8
8-1
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Item
Content
Setting
range
Default
1
AE (145)
AE (145mm/s)
200-
650
450
2
TEXT (145)
Character (145mm/s)
500
3
TEXT/PHOTO (145)
Character/Photo
(145mm/s)
500
4
PHOTO (145)
Photo (145mm/s)
500
5
TONER SAVE (145)
Toner save (145mm/s)
400
6
AE (122)
AE (122mm/s)
400
7
TEXT (122)
Character (122mm/s)
450
8
TEXT/PHOTO (122)
Character/Photo
(122mm/s)
450
9
PHOTO (122)
Photo (122mm/s)
450
10
TONER SAVE (122)
Toner save (122mm/s)
376
SIMULATION 8-1
426
1/1
DV BIAS COPY SETTING. INPUT VALUE 200-550, AND PRESS
START.
1: AE
426
2: TEXT
450
3: TEXT/PHOTO
450
4: PHOTO
450
5: SUPER/PHOTO
400
6: TONER SAVE
376
SIMULATION 8-1