AR-168N/168L TEST COMMAND, TROUBLE CODES 10 - 21
46
19
Exposure mode setting (AE
MODE)
[Function]
<
γ
table setting>
When this test command is executed, the code number of the current set gamma table is displayed.
(Default: Japan -1/Ex Japan -2)
Enter the code number corresponding to the desired gamma table, and press [
←
/
→
] key to change
the mode and write into the EEPROM.
<AE operation mode>
When setting the
γ
table, press [
→
] key to change to the AE operation mode, and the current set code
number of the AE operation mode is displayed. (Default: 0)
Enter the code number corresponding to the desired AE operation mode and press [
←
/
→
] key to
change the mode and write into the EEPROM.
<PHOTO image process setting>
When [
→
] key is pressed in AE operation mode setting, the mode is changed to the PHOTO image
process setting and the code number of the current set PHOTO image process setting is displayed.
(Default: 0)
Enter the code number corresponding to the desired PHOTO image process setting and press [
←
/
→
]
key to change the mode and write into the EEPROM.
[Operation]
20
SPF exposure correction
(EXP.LEVEL SPF) (Disabled
when set to OC)
[Function]
Used to adjust the exposure correction amount in the SPF mode. The adjustment is made by adjust-
ing Vref voltage variation for the OC mode.
When this test command is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to save the setting and make a copy.
When the set value is increased, copy becomes darker. When the set value is decreased, copy
becomes lighter. (Adjustment range: 1 – 99)
[Operation]
The operation is similar to test command 46-01.
Main
code
Sub
code
Contents
Details of function/operation
Mode
Display item
Code number
Setting content
Remark
γ
GAMMA
1
Image quality priority mode
Japan default
2
Toner consumption priority mode
EX Japan default
AE
AE
0
Lead edge stop
Default
1
Real time process
PHOTO
PHOTO
1
Error diffusion process
Default
2
Dither process
1) Initial display
<
γ
table setting>
2) [
→
] Mode selection
2) [
←
] Mode selection
3) [10KEY] Value input
4) [ENTER/START] Save the
set value. The machine
goes to the sub code entry
standby mode.
46-19 AE MODE
GAMMA 2( 1-2)
46-19 AE MODE
AE 0( 0-1)
46-19 AE MODE
PHOTO 1( 1-2)
46-19 AE MODE
AE 1( 0-1)
Mode
Display item
Default
Remark
SPF
SPF
50
10̲TESTCOMMAND.fm 21 ページ 2005年11月18日 金曜日 午後5時37分