AR-168N/168L TEST COMMAND, TROUBLE CODES 10 - 15
26
43
Side void amount setting
(SIDE VOID)
[Function]
When this test command is executed, the currently set code of the side void quantity is displayed (ini-
tial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm))
∗
When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of “Set value x 0.5mm”
is made.)
[Operation]
62
Energy-save mode copy
lamp setting (C-LAMP E-S)
[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
When this test command is executed, the current set code number is displayed. Enter the desired
code number and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
30
01
Paper sensor status display
(P-SENSOR)
[Function]
The paper sensor status is displayed on the LCD.
∗
Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.
∗
The width sensor is available only in the FAX models.
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
9
Code
Setting
Remark
0
0 mm
1
0.5 mm
2
1.0 mm
3
1.5 mm
4
2.0 mm
Default
5
2.5 mm
6
3.0 mm
7
3.5 mm
8
4.0 mm
9
4.5 mm
10
5.5 mm
1) Initial display
2)
[
10KEY]
3) [ENTER/START]
26-43 SIDE VOID
4( 0-10)
26-43 SIDE VOID
5( 0-10)
26-43 SIDE VOID
5( 0-10)
Code number
Setting
Display item
Remark
0
Copy lamp OFF
OFF
1
Copy lamp half-ON
ON
Default
Sensor
Display item
Remark
Paper exit sensor
POD
No. 1 tray paper width sensor
PD1
Paper entry sensor
PPD1
Duplex sensor
PPD2
No. 2 tray paper feed sensor
PPD3
New drum cartridge sensor
DRST
1) Initial display
2) When sensor ON
30-01 P-SENSOR
30-01 POD PD1 PD2
PPD1 PPD2 PPD3 DRST
10̲TESTCOMMAND.fm 15 ページ 2005年11月18日 金曜日 午後5時37分