AR-168N/168L TEST COMMAND, TROUBLE CODES 10 - 17
43
05
Fusing temperature setting
in duplex copy (FU TEMP
DPLX) (Enabled when
Duplex setting is ON)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
14
Fusing start temperature
setting (FU TEMP START)
[Function]
When this test command is started, the currently set code number is displayed.
Press [
←
/
→
/10KEY] to switch the setting, and press [ENTER/START] key to save it to the EEPROM.
The machine goes to the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents
Details of function/operation
Code
Shift temperature (°C)
Remark
0
±0
Default
1
-8
2
-6
3
-4
4
-2
5
±0
6
+2
7
+4
8
+6
9
+8
Code
Set temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200
10̲TESTCOMMAND.fm 17 ページ 2005年11月18日 金曜日 午後5時37分