AR-168N/168L TEST COMMAND, TROUBLE CODES 10 - 14
26
30
CE mark support control ON/
OFF (CE MARK)
[Function]
When this test command is executed, the current set CE mark support control is displayed. Enter the
code number corresponding to the desired CE mark support control and press [ENTER/START] key
to save the setting.
[Operation]
The operation is similar to test command 21-01.
37
Cancel of stop at developer
life over (DVLP LIFE END)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
39
Memory capacity check
(MEM.CHK)
[Function]
When the test command is executed, the currently installed SDRAM of the main unit is displayed.
[Operation]
40
Polygon motor OFF time
setting (Time required from
completion of printing to
turning OFF the motor) (LSU
MOTOR OFF)
[Function]
When this test command is executed, the current setting is displayed. Enter the code number corre-
sponding to the desired setting and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
42
Transfer ON timing control
setting (TC ON TIMING)
[Function]
When this test command is executed, the currently set value of the transfer ON timing is displayed
(initial display), and the set value is saved. (Setting range: 0 – 9, Default: 5)
∗
The default “5” of transfer ON timing is “330ms passed from PS release.”
∗
When set to “0,” it is the same as setting to “5.”
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents
Details of function/operation
Code number
Setting
Display item
Remark
0
CE mark support control OFF
OFF
Default (100V series)
1
CE mark support control ON
ON
Code number
Setting
Display item
Remark
0
Stop at developer life over
STOP
1
Cancel of stop at developer life over
NONSTOP
Code number
Setting
Remark
8
8 MBYTE
1) Memory capacity display
26-39 MEM.CHK
8 MBYTE
Code number
Setting
Display item
Remark
0
0sec
0 SEC.
1
30sec
30 SEC.
Default
2
60sec
60 SEC.
3
90sec
90 SEC.
Code
Setting
Remark
0
0 msec
1
–40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
0 msec
Default
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
10̲TESTCOMMAND.fm 14 ページ 2005年11月18日 金曜日 午後5時37分