
Manual – MOVIPRO® SDC with DeviceNet Interface
151
Index
P852 User-defined unit ........................................119
P86x Modulation ..................................................119
P860 PWM frequency 1 .......................................119
P861 PWM frequency 2 .......................................119
P862 PWM fix 1 ...................................................119
P863 PWM fix 2 ...................................................119
P864 PWM frequency CFC..................................120
P87x Process data description.............................120
P870 Setpoint description PO1 ............................120
P871 Setpoint description PO2 ............................120
P872 Setpoint description PO3 ............................120
P873 Actual value description PI1 .......................120
P874 Actual value description PI2 .......................120
P875 Actual value description PI3 .......................120
P876 PO data enable...........................................121
P9xx IPOS parameters ........................................121
P90x IPOS reference travel .................................121
P900 Reference offset .........................................122
P901 Reference speed 1 .....................................122
P902 Reference speed 2 .....................................122
P903 Reference travel type .................................122
P904 Reference travel to zero pulse....................124
P905 Hiperface offset ..........................................124
P906 Cam distance..............................................124
P91x IPOS travel parameters ..............................124
P910 Gain X controller .........................................124
P911 Positioning ramp 1 ......................................124
P912 Positioning ramp 2 ......................................124
P913/P914 Travel speed CW/CCW .....................125
P915 Velocity precontrol ......................................125
P916 Ramp type ..................................................126
P917 Ramp mode ................................................126
P918 Bus setpoint source ....................................126
P92x IPOS monitoring .........................................127
P920 SW limit switch CW.....................................127
P921 SW limit switch CCW ..................................127
P922 Position window ..........................................127
P923 Lag error window ........................................127
P924 Positioning interruption detection................127
P93x IPOS special functions................................128
P930 Override ......................................................128
P933 Jerk time .....................................................128
P938 speed task 1 ...............................................128
P94x IPOS encoder .............................................129
P941 Source of actual position ............................129
P948 Automatic encoder replacement detection .129
P96x IPOS modulo function.................................129
P960 Modulo function ..........................................129
P961 Modulo numerator ......................................129
R
Ramp
Process data......................................................58
Ramp generators ...................................................93
Ramp mode .........................................................126
Ramp monitoring ...................................................95
Ramp monitoring 1 ................................................95
Ramp monitoring 2 ................................................95
Ramp type ...........................................................126
Ramp t11/t21 up/down CCW/CW ..........................93
Ramp t12 UP=DOWN............................................94
Ramp t22 UP=DOWN............................................94
Rated output current ..............................................92
Reference offset ..................................................122
Reference speed 1 ..............................................122
Reference speed 1/2 ...........................................122
Reference speed 2 ..............................................122
Reference travel to zero pulse.............................124
Reference travel type...........................................122
Register object.......................................................42
Repair ....................................................................21
Reset behavior.....................................................118
Reset statistics data.............................................116
Response to brake wear......................................107
Response to oil aging/fault ..................................106
Response to oil aging/warning.............................106
Response to vibration/fault ..................................106
Response to vibration/warning ............................106
Response to "External fault" ................................117
Response to "Lag error" ......................................118
Response to "Motor overload" .............................118
Response to "Positioning interruption" ................118
Response to "SW limit switch" .............................118
Response to "TF signal" ......................................118
Response to "Timeout SBus 1" ...........................118
Response to "Timeout SBus 2" ...........................118
Restart time .........................................................119
Return codes
Additional code ..................................................49
Definitions ..........................................................50
DeviceNet-specific .............................................46
General error codes...........................................47
MOVILINK
®