11
MOVIPRO
®
SDC error list
Service
102
Oil aging warn-
ing
Display error
(P)
0
Oil aging warning
Error message from the
oil aging sensor
Schedule oil change
103
Oil aging error
Display error
(P)
0
Oil aging error
Error message from the
oil aging sensor
SEW-EURODRIVE recom-
mends that you change the
gear unit oil immediately.
104
Oil aging over-
temperature
Display error
(P)
0
Oil aging overtemperature
Overtemperature sig-
nal from the oil aging
sensor
•
Let oil cool down
•
Check if the gear unit cools
properly
105
Oil aging ready
signal
Display error
(P)
0
Oil aging ready signal
Oil aging sensor is not
ready for operation
•
Check voltage supply of oil
aging sensor
•
Check and, if necessary,
replace the oil aging sensor
106
Brake wear
Display error
(P)
0
Brake wear error
Brake lining worn
Replace brake lining (see
"Motors" operating instructions)
110
"Ex-e protec-
tion" error
Emergency
stop
0
Duration of operation below 5
Hz exceeded
Duration of operation
below 5 Hz exceeded
•
Check configuration
•
Shorten duration of
operation below 5 Hz
116
"Timeout" error
Rapid stop/
warning
0
Internal communication time-
out
•
Check startup
•
Check wiring
Error
Suberror
Code Designation
Response (P) Code Designation
Possible cause
Measure