Unit replacement
Service
6. Switch on the new MOVIPRO
®
unit.
7. Now the parameters stored on the card are available. If you want the new
MOVIPRO
®
unit to have a different parameter set, change the parameter set now,
and save the changes on the memory card after startup.
8. For applications with motor encoder or synchronous encoder, you have to perform a
reference travel.
1952918283
Restoring the data backup of the communication and control unit.
7-segment display:
Status LED S2: Flashes green/orange
This can take several minutes.
Do not switch off the MOVIPRO
®
unit during this time.
The data of the communication and control unit has been restored. Perform a DC 24 V reset
by switching the MOVIPRO® off and then back on again.
7-segment display:
Status LED S2: Flashes green
Status LED S3: Lights up green
Boot sequence in progress.
7-segment display:
–
Restoring the data backup of the power section.
7-segment display:
Status LED S2: Flashes green
Status LED S3: Lights up green
7-segment display:
Status LED S2: Flashes green
Status LED S3: Lights up green
The data backup has been completely restored.
3 seconds