Manual – MOVIPRO® SDC with DeviceNet Interface
10
Startup assistant
Parameterization of MOVIPRO
®
4. Select the motor type and click [Next].
Enter the following values according to the motor configuration:
• Nominal motor voltage [1]
• Nominal motor frequency [2]
• Nominal line voltage [3]
• Error response [4]
• Temperature sensor type [5]
5. Choose whether you want to use the encoder and click [Next].
6. Select the operating mode of the drive.
To use the drive as a hoist, select the "Hoist" operating mode. The required param-
eters are now set automatically.
NOTE:
Startup as a hoist is not possible in "CFC" operating mode.
To use an application module, select the "Positioning with IPOS
®
" operating mode.
For more information about application modules, refer to section "Application mod-
ules in MOVITOOLS
®
MotionStudio (page 8)".
Click [Next] to continue.
7. Select the control mode of the drive and click [Next].
2071890571
[1] "Rated motor voltage" edit box
[2] "Rated motor frequency" edit box
[3] "Rated line voltage" edit box
[4] "Error response" selection list
[5] "Temperature sensor type" selection
list
[1]
[2]
[3]
[4]
[5]
0