24
ENGLISH
1. Light doesn‘t power up when (Button 1 ON/OFF) is pressed
a) Is light head plug inserted all the way? Make sure plug is inserted fully and locking ring turned clockwise.
b) Is the battery charged up? Recharge battery fully.
2. Light comes on but flickers when (Button 1 ON/OFF) is pressed
a) Incompatible battery fitted in SETO POWER LED base unit - only use approved replacement batteries available
through your point of purchase.
b) Battery to light head communication fault – press (Button 1) off then on – If problem still persists unplug the
light head completely for 2 minutes then replace plug and retry.
3. The external battery charger won‘t recharge the battery
a) Is charger plug inserted all the way? Make sure plug is inserted fully and locking ring turned clockwise.
b) Has battery been left completely flat for an extended period of time? Contact us.
4. The integrated (Vepac) charger shows no LED indication of the charging process
a) Supply cable from vehicle is not connected or there is a poor connection – check supply and connections from
the DC power source.
b) Supply voltage is not high enough to trigger the charger to start - check supply voltage is 13 volts DC or higher
(vehicle must be running with alternator charging the supplying battery). Supply cable must be of adequate size
to prevent voltage drop from the supplying battery to the SETO POWER LED charging lead.
c) The SETO POWER LED internal battery is not connected – battery has been left too long in a discharged state,
the battery will need replacing.
5. The internal (Vepac) charger shows a rapidly flashing function
a) This is a fault indication, the charger has timed after 18 hours because it can‘t recharge the battery - replace the
battery with the approved type.
TROUBLESHOOTING
CONFORMANCE
CE Marked. This product has been tested and conforms to EN 61000-6-3 and 61000-6-4.
OPTIONAL REMOTE CONTROL
Contains Transmitter Module FCC ID: 0A3MR24J40MA
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause undesired operation.