SOS Mode
The unit may be set to flash the LED‘s in the SOS sequence if the need ever arises. To do this, switch on, select the
power level (brightness) you wish to use (8%, 25%, 50%, 75%, 100% or 125%). Next press the MODE button twice,
pressing the SELECT button allows the inner outer or both channels of LEDs to be run..
Lighting Mode
The unit may be set to constantly flash the LEDs to provide a warning signal to others. To select this option first
switch on, select a power level you wish to use (8%, 25%, 50%, 75%, 100% or 125%) then press the MODE switch
once, pressing the SELECT button allows the inner, outer or both channels of LEDs to be run.
Battery Status Indicator
A low battery warning with cut-off function is included with your SETO POWER LED to help prevent deep di-
scharging the high performance cyclic SLA battery. Deep discharging can lead to shortened operating time and
shortened battery life. Please note, to avoid consequential damage, the battery must be recharged within 24
hours after use, regardless of how long it has been operated.
The user is signalled to help pre-warn of the amount of energy left in the battery able to run the LED light in 3
ways: 3 colour LED, audible bleeper and flashing of the LEDs on the main panel. As the fully charged battery di-
scharges, the indicator LED (located next to the power on / off switch) will show green.
As the battery discharges further this indicator LED will change from green through to amber. At this point the
unit will give an audible bleep and blink the main LEDs once to alert the user that a stage has been reached in the
discharge process.
The next change is when the LED indicator changes from amber to red; here again the user will hear an audible
bleeb and see a blink of the main LEDs to signal another change nearer to the end of battery duration.
Finally the indicator LED will change from constant red to flashing red where upon the lamp brightness will default
from any of the power settings down to 25%, the beeper will then sound every 30 seconds and at the same time
the main LEDs will blink once. This process will continue until the battery voltage falls to a point where the unit will
automatically switch off. This process will give users adequate time to retreat to an area of safety without being
left in the dark.
The light should not be switched back on until the battery has been recharged to prevent deep discharge and
possible irreversible damage to the battery.
Light Management
The unit features a retractable vari-focus system to allow a tightly focused spot beam through to a fully diffused
flood of light so any working environment can be catered for. Use the two control knobs together to move the
diffuser blind up and down in front of the LEDs, as the blind gradually passes over the LEDs you‘ll notice the pro-
jected light pattern change.
Adjusting Beam from Spot to Flood
INCREASE
SPOT
INTENSITY
INCREASE
FLOOD
INTENSITY