Contents
MultiExact Gas Analyser
Adjusting the backlight timer.................................................................... 39
Changing regional settings ...................................................................... 40
Selecting communications type ............................................................... 40
Setting up automatic validation/calibration (option) ...................................... 41
Overview of automatic validation/calibration ........................................... 41
Automatic validation/calibration sequence .............................................. 42
Remote calibration or automatic validation/calibration ............................ 45
Automatic validation/calibration target and tolerance .............................. 46
Automatic validation/calibration type and mode ...................................... 47
Automatic validation/calibration phases .................................................. 47
Automatic validation/calibration timers .................................................... 49
Configuring and using the mA outputs (option) ............................................ 51
Introduction to the mA output parameters ............................................... 51
Setting up the mA output parameters ...................................................... 53
Configuring and using the voltage outputs (option) ...................................... 57
measurements for background gases (purity or control only) 57
Overview of measurement errors ............................................................ 57
Entering a cross-interference (X-Interference) compensation ................ 58
Configuring the measurement alarms .......................................................... 60
Alarm modes and levels .......................................................................... 60
Latching/non-latching alarms ................................................................... 62
Viewing the measurement alarm status .................................................. 63
Initiating an automatic validation/calibration ............................................ 68
Automatic validation/calibration status indications .................................. 69
Stopping an automatic validation/calibration ........................................... 70
Viewing validation/calibration history ....................................................... 71
Calibrating the pressure transducer (O
purity only) .................................... 72
GENERAL OPERATION .............................................................................. 74
purity and control only) ................................... 75
Switching pressure compensation on/off ................................................. 75
Viewing pressure effected measurements (option) ................................. 76
Checking the voltage output (option) ............................................................ 77
ii
05410001A / Revision 6