SerVision
Embedded Video Gateway System Guide
Defining Alternate Outlines
154
Note:
If a device is not enabled in the Default outline, it cannot be enabled in any other outline. In this case,
the configuration screen of the device in the outline section will say the device is disabled (see figure 181). For
information about activating a device in the Default outline, see page 120.
Figure 181: Device that is not enabled in the Default outline
7. Select the desired settings for the device in the current outline.
Note:
For information about the settings, please refer to the section of this manual that relates to each type of
setting, as follows:
Note:
If VMD is enabled for a camera in the default outline, it cannot be disabled in any other outline.
Similarly, VMD regions can only be defined and modified in the default outline; they are applied in all
outlines in accordance with their definitions in the default outline.
Configuring Sensor and Activator
Note:
In the
Camera
screens, when recording is
by event
, the sensors and activators can only be selected
as triggers if they are already enabled in the current outline. Thus, for example, if you want to select
Sensor 1 as a trigger for the Camera 1 recorder, you must first enable Sensor 1 in its configuration screen,
and then select it in the Camera 1 configuration screen.
8. Click
Update
.
9. Repeat steps 6–8 for each of the cameras, sensors, and activators connected to the Video Gateway.
10. Save the changes. The settings will be implemented after the unit is restarted (see
Activating Outlines Manually
If more than one outline is defined, and outline switching is not performed automatically by the system (by means
of Sensor 1 or through a schedule), you can manually select the outline you want to run at any time. In addition, you
can specify that the selected outline be loaded automatically when the unit first starts up. In this case, the selected
outline replaces the
Default
outline as the system default.