Control
27
Menus
Menu Text
Description
Adjustable by:
CMP.A
ADD1
ADD 2
USER
USER
USER
USER
ADD 3
OFF
When the value (testing) reaches the value setting by user,
USER
the system will be closed.
When the value (testing) reaches the value setting by user,
the compressor will be start-up.And the value(testing) under
the value(setting),the compressor will be closed.
When the value (testing) reaches the value setting by user,
the ADD1 will be start-up.And the value(testing) under
the value(setting),the ADD1 will be closed.
When the value (testing) reaches the value setting by user,
the ADD2 will be start-up.And the value(testing) under
the value(setting),the ADD2 will be closed.
When the value (testing) reaches the value setting by user,
the ADD3 will be start-up.And the value(testing) under
the value(setting),the ADD3 will be closed.
Degree Minute = The corresponding value of temperature difference between the actual water
supply and the desired water supply X time
(through
integral
to change; every minute for a
cumulative)
Temperature difference between the
actual water supply and the desired
water supply (
℃
)
The corresponding value
-31 ~ -40
-40
-21 ~ -30
-30
-11 ~ -20
-20
-1 ~ -10
-10
1 ~ 10
10
11 ~ 20
20
21 ~ 30
30
31 ~ 40
40
Degree Minute s(DM) instruction
For example:
(
Under
desired temperature)
Actual water supply temperature decrease 1
℃
(
under
desired temperature) in 1 minutes,
Degree Minute=-10 X 1= -10;
Actual water supply temperature continue decrease 2
℃
(
under
desired temperature) in another 1
minutes,
Degree Minute=-10 X 1 + (-10) = -20;
Actual water supply temperature continue decrease 3
℃
(
under
desired temperature) in another 1
minutes,
Degree Minute=-10 X 1 + (-20) = -30;
Actual water supply temperature continue decrease 4
℃
(
under
desired temperature) in another 1
minutes,
Degree Minute=-10 X 1 + (-30) = -40;
……………………
Содержание AWA-SS-10
Страница 2: ......
Страница 21: ...Electrical connection 19 Wiring Diagram 230V 50 HZ ...
Страница 22: ...Electrical connection 20 Wiring Diagram 3X400V 3 50 HZ ...
Страница 46: ...44 1 11 3 2 4 5 6 7 9 10 12 13 14 8 9 Component placement Please Note The picture for reference only ...
Страница 48: ...Component placement 3X400 V 3 50 HZ 230 V 50 HZ 70 71 70 71 46 Please Note The picture for reference only ...