Control
39
Regular Checks
Checking the Safety
Valves
Both safety valves of the heating system should be checked at least four times a year to prevent lime deposits to
clog the mechanism. To find out where the safety valves are located.
The safety valve of the water heater protects the closed heater against positive pressure. It is fitted on the cold
water inlet line, its outlet opening facing down- wards. If the safety valve is not checked regularly, the water heater
might be damaged. It is quite normal that the safety valve lets out small amounts of water when the water heater is
being charged, especially if a lot of warm water was used previously.
To check the safety valves, give the cap a quarter of a turn clockwise until the valve lets out some water through
the overflow pipe.
If a safety valve does not work properly, it must be replaced. Check with your installation contractor.
The opening pressure of the safety valve is not adjustable.
In
the Event
of
Leakage
In the event of leakage in the warm water lines between unit and water taps, the shut-off valve on the cold water
inlet line should be closed immediately.
Call
your
installation
contractor
. In the event of leakage in the system circuit, turn off the heat pump and
call your installation contractor immediately.
Содержание AWA-SS-10
Страница 2: ......
Страница 21: ...Electrical connection 19 Wiring Diagram 230V 50 HZ ...
Страница 22: ...Electrical connection 20 Wiring Diagram 3X400V 3 50 HZ ...
Страница 46: ...44 1 11 3 2 4 5 6 7 9 10 12 13 14 8 9 Component placement Please Note The picture for reference only ...
Страница 48: ...Component placement 3X400 V 3 50 HZ 230 V 50 HZ 70 71 70 71 46 Please Note The picture for reference only ...