Control
25
• OPERATION OFF
Heat pump is turned off. The following text is displayed on the control panel: “OPERATION OFF “
If the heat pump will be put in OPERATION OFF mode during winter, please remember to let out all the water
the heating system to avoid any damage caused by freezing.
Menus
If you wish to change operating mode:
a. Open the main menu INFORMATION by pressing the right-
hand button once.
You will find the
sub-menu named OPERATION.
b. Open the OPERATION menu by pressing the right-hand button once.
c. Select the desired mode by pressing either the ”up” or ”down” button.
d. Return to the main menu by pressing the
left-hand button twice.
”up” button until to the top,and press
Sub-Menu
HEAT
CURVE
T
his
menu
is
used
for
making
adjustments that affect the room temperature.For more information, please refer
to ”Adjustments to be made regularly” on page 30.
Table 1: Menu– HEAT CURVE
Menu Text
Description
Adjustable by:
The value entered shows the temperature of the water to be
(see”Adjustment
CURVE distributed to the radiators(supply line temperature) when the of CURVE value” on p. 31)
outside air temperature is 0°C.
MIN Adjustment of value for lowest supply line temperature User (see ”Adjustment of MIN
allowed.
and MAX values” on p. 35)
MAX Adjustment of value for highest supply line temperature User (see ”Adjustment of MIN
allowed.
and MAX values” on p. 35)
CURVE 5 Adjustment of room temperature when the outside User (see ”Adjustment of
air temperature is +5°C.
CURVE value” on p. 34)
CURVE 0 Adjustment of room temperature when the outside User (see ”Adjustment of
air temperature is 0°C.
CURVE value” on p. 34)
CURVE – 5 Adjustment of room temperature when the outside User
(see
”Adjustment
of
air temperature is -5°C.
CURVE value” on p. 34)
Production of radiator heat is stopped when outside air
HEAT STOP temperature is equal to or higher than the value for User, if require
heat stop entered
HEATCURVE
CURVE
MIN
MAX
CURVE
5
CURVE
0
CURVE
-
5
HEAT
STOP
40
22
70
0
0
0
17
User
Содержание AWA-SS-10
Страница 2: ......
Страница 21: ...Electrical connection 19 Wiring Diagram 230V 50 HZ ...
Страница 22: ...Electrical connection 20 Wiring Diagram 3X400V 3 50 HZ ...
Страница 46: ...44 1 11 3 2 4 5 6 7 9 10 12 13 14 8 9 Component placement Please Note The picture for reference only ...
Страница 48: ...Component placement 3X400 V 3 50 HZ 230 V 50 HZ 70 71 70 71 46 Please Note The picture for reference only ...