Sub-Menu
OPERATING TIME
OPERATION
TIME
HEATPUMP
ADD1
ADD2
ADD3
WARMWT
2
H
1
H
0
H
0
H
0
H
Table 3: Menu OPERATING TIME
Menu Text
Description
Adjustable
:
HEATPUMP
Total operating hours of heat pump since
USER
installation. Operating time will not be reset to zero.
ADD 1
Total
operating
hours
of
auxiliary
heater
(3kW) since installation. Operating time will
not be reset to zero.
ADD 2
Total operating hours of auxiliary heater
(6kW) since installation. Operating time will
not be reset to zero.
WARMWT
Total operating hours of water heater
since installation. Operating time will
not be reset to zero.
ADD 3
Total
operating
hours
of
auxiliary
heater
(9kW) since installation. Operating time will
not
be
reset to zero.
USER
USER
USER
USER
Control
29
Menus
Sub-MenuMAN TEST
Sub-Menu RESET
Reset to factory setting value.
The Sub-Menu MAN TEST contains ADD1 / ADD2 / ADD3 / HEAT PUMP / 3 WAY
MAN
TEST
ADD1
ADD2
ADD3
OFF
HEAT
PUMP
3
WAY
WARM
PUMP
OFF
OFF
OFF
OFF
OFF
4 WAY / WARM PUMP ; You can choose ON / OFF to control the each part for testing.
How to enter the Sub-Menu MAN TEST:
You need to choose the "MAN TEST" on the main menu ( INFORMATION)
And press the right button for 3 second .
4
WAY
OFF
Содержание AWA-SS-10
Страница 2: ......
Страница 21: ...Electrical connection 19 Wiring Diagram 230V 50 HZ ...
Страница 22: ...Electrical connection 20 Wiring Diagram 3X400V 3 50 HZ ...
Страница 46: ...44 1 11 3 2 4 5 6 7 9 10 12 13 14 8 9 Component placement Please Note The picture for reference only ...
Страница 48: ...Component placement 3X400 V 3 50 HZ 230 V 50 HZ 70 71 70 71 46 Please Note The picture for reference only ...