Control
24
Menus
Main Menu INFORMATION
To open the main menu INFORMATION, press the right- or left-hand button once.
To
select
the
desired
sub-menu
use
the
up
or
down
button.
Open the menu by pressing the right-hand button once.
To return to the main menu, press the left-hand button once.
INFORMATION
OPERATION
HEATCURVE
TEMPERATURE
INTEGRAL
OPER
.
TIME
RESET
MAN
TEST
Sub
menus
Return
Open
next
menu
Sub-Menu OPERATION
This menu is used for the selection of operating mode. The control system allows for five different operating
modes:
•
OPERATION AUTO
Heat pump and auxiliary heater are regulated automatically by the control system. The text
“OPERATION AUTO” will be displayed on the control panel.
•
OPERATION HEAT PUMP
Heat pump (compressor) operation is allowed by the control system.
•
OPERATION ADD.HEAT
The
auxiliary
heater
will/will not
be
allowed to operate.
This
operating
mode is normally used when a new
installation is being put into service, before the Brine system is ready for use.
•
OPERATION
WARMWATER
The heat pump will only produce warm water; no heat will be distributed to the heating system. The
text”OPERATION WARMWATER “will be displayed on the control panel.
ON
•
OPERATION HEAT PUMP
Heat pump (compressor) operation is
allowed by the control system.
OFF
not
ON/OFF
•
OPERATION
ROOMHEAT
The
heat
pump
only;
will
be
distributed to the heating system
text
”
OPERATION WARMWATER
“
will be displayed on the control panel.
The
The
heat
pump will not produce warm water.
OPERATION
AUTO
ROOMHEAT
WARMWATER
HEATPUMP
ADD
.
HEAT
ON
OFF
DEFROST
Содержание AWA-SS-10
Страница 2: ......
Страница 21: ...Electrical connection 19 Wiring Diagram 230V 50 HZ ...
Страница 22: ...Electrical connection 20 Wiring Diagram 3X400V 3 50 HZ ...
Страница 46: ...44 1 11 3 2 4 5 6 7 9 10 12 13 14 8 9 Component placement Please Note The picture for reference only ...
Страница 48: ...Component placement 3X400 V 3 50 HZ 230 V 50 HZ 70 71 70 71 46 Please Note The picture for reference only ...