Model PIM-3 10-9
10.8
WJ
Write Automatic Limit Report
SYNOPSIS
WJ0
- Turns off automatic limit reporting
WJ1
- Turns on automatic limit reporting
DESCRIPTION
The
WJ
command controls whether or not the PIM-3 will automatically trans-
mit the status of the limits whenever any one of the limits has been switched
from “off” to “on.”
If the first character of the information field is a “1”, then the PIM-3 will auto-
matically transmit the limit status whenever any one of the limits has been
switched from “off” to “on.” A sample limit status message looks like this:
#AA L1 ON L2 OFF L3 OFF L4 OFF
Where “AA” is the address of the PIM-3.
EXAMPLE
#00WJ1
The above command, when followed by a carriage return, will cause the
instrument addressed as “00” to enable its automatic limit reporting function.
WHEN TO USE IT
The automatic limit function can be used to signal that the transducer has
tripped one of the limits.
This command should always be set to “off” when using multiple RS-485
PIM-3’s on the same communications link.
Содержание PIM-3
Страница 1: ...2080 Arlingate Lane Columbus Ohio 43228 614 850 5000 DIGITAL INLINE AMPLIFIER MODEL PIM 3 ...
Страница 6: ...NOTES ...
Страница 10: ...1 4 Introduction ...
Страница 16: ...3 4 Block Diagram ...
Страница 18: ...4 2 Mounting and Wiring ...
Страница 23: ...Model PIM 3 4 7 ...
Страница 24: ...4 8 Mounting and Wiring ...
Страница 32: ...6 6 Command Format ...
Страница 35: ...Model PIM 3 7 3 ...
Страница 36: ...7 4 RS 232 Installation Notes ...
Страница 46: ...9 4 Application Programs Figure 9 1 Windows 3 1 Terminal Communications Settings ...
Страница 58: ...10 12 System Commands ...
Страница 74: ...11 16 Amplifier Commands ...
Страница 77: ...Model PIM 3 12 3 ...
Страница 79: ...Model PIM 3 12 5 ...
Страница 97: ...A 8 Appendix ...